• Distribution and Terminal Boxes
  • Control and Automation Cabinets
  • Lighting Equipment
  • Control and Indicating Stations
  • Visual, Audible and Signaling Devices
  • Electrical Heating and Fans
  • Video Surveillance
  • IT equipment
  • Spark protection barriers and functional safety relays
  • Cable Glands, Conduits
  • Sockets, Plugs, Extension cords
  • Switches, Selectors Switches, Sensors
  • Control and Measuring Instruments
  • Cable/Pipe Transits
  • Electrical Components and Materials
Logo

GIP-1300 vibration level indicator

Product Description

GIP-1300 vibrating level switches are designed to control and monitor the maximum levels of liquid and bulk media in tanks, containers, and process units.

Advantages

  • High accuracy at any temperature and density of the working environment.
  • Chemically resistant design for monitoring the level of acids, alkalis and other chemically active liquids.

Compliance with standards

GOST 31610.0-2019 (IEC 60079-0:2017)

Certificates

Markings

Explosion protection marking
1Ex db IIC T6…T2 Gb X
Ex tb IIIC T80°C… T250°C Db X
0Ex ia IIC T6…T2 Ga X
Ex ia IIIC T80°C… T250°C Da X
Degree of protection
IP66
Installation
Explosive zones of classes 0 and/or 1 and/or 2 of indoor and outdoor installations in which mixtures assigned to categories IIA, IIB, IIC may be formed according to GOST IEC 60079-10-1-2013, explosive zones of classes 21 and 22 of indoor and outdoor installations in which mixtures assigned to categories IIIA, IIIB, IIIC may be formed according to GOST 31610.10-2-2017/IEC 60079-10-2:2015, according to Ex-marking

Technical data

Ambient temperature, °C
-61... +85
Density of the measured medium, kg/m3
450 - 1800
Nominal voltage
24 VDC
220 VAC
Sensor length, mm.
≤ 6000 (up to 8000 special order)
Joining the process
Thread:
G 3/4"; G 1"; M27x2; M33x2; NPT 3/4"; NPT 1"
Flanges:
GOST 33259-2015;
EN10921-1;
ANSI/ASME B16.5
Material of parts in contact with the environment
AISI 304, AISI 304L, AISI 316, AISI 316L, AISI 321, AISI 304 steel with PFA coating, Others on request
Operating pressure range, MPa
-0,1…10
Operating temperature range, °C
-40...+250
Output signal
DPDT
PNP/NPN
8/16 mA
NAMUR
Enclosure material
Aluminum
Stainless steel (AISI 304)

Design parameters

For measuring liquid media:

For standard temperatures from minus 40 to plus 150 C. L ≥ 55 mm
Process connection ≥ 3/4""
For high temperatures from minus 61 to plus 250 C. L ≥ 55 mm
Process connection ≥ 3/4"

For measuring bulk solids:

For standard temperatures from minus 40 to plus 150 C. L ≥ 220 mm
Process connection ≥ 1"
For high temperatures from minus 61 to plus 250 C. L ≥ 220 mm
Process connection ≥ 1 1/2"

For measuring liquid/bulk media

For standard temperatures from minus 40 to plus 150 C. L ≥ 110 mm
Process connection ≥ 1"

Additional information

Data for the formation of mnemonics
Х1-Х2-Х3-Х4-Х5.Х6.Х7.Х8-Х9.Х10.Х11.Х12-Х13.Х14-Х15-Х16/Х17 – TU 26.51.52-096-72453807-2024
X1 – series of products: GIP
X3 – case material: no designation – aluminum alloy,
H – stainless steel;
X4 – presence and type of explosion protection: O – non-explosion-proof (general industrial) design,
I – explosion protection type “intrinsically safe electrical circuit “i”,
B – explosion protection type “flame-proof enclosure “d”,
VP – explosion protection type against dust ignition by enclosures “t”,
GDP – combination of explosion protection types “d” and “t”;
X5 – type of measured environment: L – liquid
C – bulk
X6 – temperature of the controlled environment, °C: 1 – (minus 40…plus 80)
2 – (minus 40…plus 150)
3 – (minus 61…plus 250)
Х7 – pressure of the controlled environment, MPa: 006 – 0,6
010 – 1
016 – 1,6
025 – 2,5
040 – 4
063 – 6,3
100 – 10
160 – 16
250 – 25
Х8 – density of the controlled environment, kg/m3: ХХХХ – a number specified by the user (for example, 0840 – 840 kg/m3);
X9 – process connection type: P – thread,
F1 – flange according to GOST,
F2 – flange according to EN,
F3 flange according to ASME;
X10 – thread type or flange diameter:
Thread type Flange diameter according to GOST Flange diameter according to EN Flange diameter according to ASME B16.5
01 – thread G3/4" 015 – DN15 015 – DN15 015 – DN15
02 – G1" thread 020 – DN20 020 – DN20 020 – DN20
03 – thread G1½" 025 – DN25 025 – DN25 025 – DN25
04 – NPT thread 3/4" 040 – DN40 040 – DN40 040 – DN40
05 – NPT thread 1" 050 – DN50 050 – DN50 050 – DN50
06 – NPT thread 1½" 065 – DN65 065 – DN65 065 – DN65
07 – thread M27×2 080 – DN80 080 – DN80 080 – DN80
08 – thread M33×2 100 – DN100 100 – DN100 100 – DN100
08 – thread M33×2 150 – DN150 150 – DN150 150 – DN150
09 – other threads on request 200 – DN200 200 – DN200 200 – DN200
09 – other threads on request 250 – DN250 250 – DN250 250 – DN250
X11 – flange type (not used when selecting threads in X9): Flange type according to F1 (GOST):
G01 – Flat welded (Type 01)
Flange type according to F2 (EN):
E01 – Flat welded flange (Type 01)
Flange type according to F3 (ASME):
A01 – Flat welded. SO (Slip On)
X12 – flange sealing surface design (not used when selecting threads in X9):
F1 performance Execution according to F2 Execution according to F3
I01 – Plane (A) U01 – Type A, flat surface P01 – RF. Connecting projection
I02 – Connecting projection (B) U02 – Type B1, connecting projection (PN 2.5 to PN 40) P02 – LM. Large protrusion
I03 – Spike (C) U03 – Type B2, connecting projection (PN 63 to PN 100) P03 – SM. Small protrusion
I04 – Spike (L) U04 – Type C, spike P04 – LF. Large depression
I05 – Groove (D) U05 – Type D, groove P05 – SF. Small depression
I06 – Groove (M) U06 – Type E, protrusion P06 – LT. Large spike
I07 – Ledge (E) U07 – Type F, recess P07 – ST. Small spike
I08 – Depression (F) U08 – Type G, O-ring recess P08 – LG. Large groove
I09 – For oval section gasket (J) U09 – Type H, recess for sealing ring P09 – SG. Small groove
I10 – Under the lens gasket (K) U09 – Type H, recess for sealing ring P10 – RTG. Oval gasket recess
X13 – material of the immersion part: 01 – Stainless steel AISI 304
02 – Stainless steel AISI 316L
03 – Stainless steel AISI 321
04 – Stainless steel AISI 304 with polymer coating
Other materials on request
X14 – length of the immersion part*, mm: 0065 - 65
0080 - 80
0100 – 100
0220 – 220
ХХХХ – specify length
Note:
For bulk media, the minimum length of the immersion part:
1. 220 mm with a fork length of 150 mm;
2. 110 mm with a fork length of 100 mm.
X15 – output signal type: 01 - DPDT
02 - 8/16 mA
03 - NAMUR
04 - NPN
05 - PNP
X16 – quantity and type of connecting fittings (Cable entry): Instead of XX , indicate the quantity (Max 2 pcs.) and type of cable glands/plugs/adapters
X17 – options, accessories, versions. O - cover with glass
SHIELD - metal nameplate (additional)
RALXXX - painting in color according to customer’s requirements, XXX – code on the RAL scale
SIL - Safety Integrity Level Certificate
BIG - spark protection barrier

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Model Breakdown
1X - 2X - 3X - 4X - 5X . 6X . 7X . 8X - 9X . 10X ​ 11X . 12X - 13X . 14X - 15X - 16X / 17X – TU 26.51.52-096-72453807-2024
1X - Series of products
2X - Case size code
3X - Case material
4X - Presence and type of explosion protection
5X - Type of measured medium
6X - Temperature of the controlled environment, °C
7X - Pressure of controlled environment, MPa
8X - Density of the controlled environment, kg/m³
9X - Process connection type
10X - Thread type or flange diameter
11X - Flange type (not used when selecting threads in X9)
12X - Design of the flange sealing surface (not used when selecting threads in X9)
13X - Material of the immersion part
14X - Length of immersion part*, mm
15X - Output signal type
16X - Number and type of connecting fittings (Cable entry)
17X - Options, accessories, versions

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more