• Distribution and Terminal Boxes
  • Control and Automation Cabinets
  • Lighting Equipment
  • Control and Indicating Stations
  • Visual, Audible and Signaling Devices
  • Electrical Heating and Fans
  • Video Surveillance
  • IT equipment
  • Spark protection barriers and functional safety relays
  • Cable Glands, Conduits
  • Sockets, Plugs, Extension cords
  • Switches, Selectors Switches, Sensors
  • Control and Measuring Instruments
  • Cable/Pipe Transits
  • Electrical Components and Materials
Logo

SHGVA-VA Compact Explosion-Proof Switching Module with Automatic Circuit Breaker

Product Description

The SHGVA-VA is an explosion-proof switching module with an automatic circuit breaker designed to reliably protect electrical circuits from overloads and short circuits, as well as to safely disconnect and control lines in areas with explosive gases, including acetylene-containing environments and combustible dust. This solution is in demand in industrial power supply systems that require a combination of high safety, compactness, and flexible configuration. The module is manufactured according to the customer's specifications: from 1 to 4 poles, with a choice of rated current, cable entry types, and enclosure.

Advantages

  • Compact and space-saving – direct cable entry through Ex d-certified entries eliminates the need for additional boxes and connections.
  • Reliability in harsh conditions – the aluminum alloy housing with alloying modifiers and a protective coating and IP66/IP67 rating guarantees resistance to moisture, dust, salt fog, and aggressive environments.

Frequently bought together

Compliance with standards

GOST 14254-2015
GOST 31610.0-2014
GOST IEC 60079-1-2013
GOST IEC 60079-31-2013
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
GOST 12.2.007.0-75. Occupational Safety Standards
GOST 24754-2013
GOST 30852.0-2002
GOST 30852.20-2002
TR CU 012/2011
TR CU 004/2011
TR CU 020/2011

Certificates

Markings

Explosion protection marking
1Ex db IIC T6...T5 Gb X
Ex tb IIIC T80°С ...T100°С Db X
Marking of mining equipment
RN1, RN2
Degree of protection
IP66/IP67
Installation
Category I for firedamp and dust;
Category II for gas subgroups IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust atmospheres containing volatile particles, non-conductive and conductive dust;

Technical data

Ambient temperature, °C
-60...+40/+60
Maximum voltage, V
1000/250
Maximum current, A
160
Threads on connecting holes
2 holes with metric thread GOST 24705-2004 (other thread type and size on request)
Coating
Antistatic polymer-epoxy coating, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Enclosure material
Aluminum alloy with alloying modifiers
Protection class against electric shock
I
Weight, kg
4
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

For rated current up to 63A**

Explosion-proof switching module ШГВА-ВА with automatic circuit breaker

For rated current from 80A to 125A**

Explosion-proof switching module ШГВА-ВА with automatic circuit breaker

** For explosion-proof mine installations, Exd-rated mine terminal boxes are used.
Design parameters for 160A are available upon request.

Installation of an input housing with transition terminals is required in case of using cables with cores of a cross-section greater than:
- 25 mm2for modular circuit breakers 0.5 – 25 A;
- 35 mm2for modular circuit breakers 32 – 63 A;
- 50 mm2for modular circuit breakers 80 – 125 A.

Standard circuit breakers ШГВА-ВА
Marking for order Description
SHGVA-VA -1-6 Automatic circuit breaker 1 pole I=6 A
SHGVA-VA -1-10 Automatic circuit breaker 1 pole I=10 A
SHGVA-VA -1-16 Automatic circuit breaker 1 pole I=16 A
SHGVA-VA -1-20 Automatic circuit breaker 1 pole I=20 A
SHGVA-VA -1-25 Automatic circuit breaker 1 pole I=25 A
SHGVA-VA -1-32 Automatic circuit breaker 1 pole I=32 A
SHGVA-VA -1-40 Automatic circuit breaker 1 pole I=40 A
SHGVA-VA -1-63 Automatic circuit breaker 1 pole I=63 A
SHGVA-VA -1-80 Automatic circuit breaker 1 pole I=80 A
SHGVA-VA -1-100 Automatic circuit breaker 1 pole I=100 A
SHGVA-VA -1-125 Automatic circuit breaker 1 pole I=125 A
SHGVA-VA -1-160 Automatic circuit breaker 1 pole I=160 A
SHGVA-VA -2-6 Automatic circuit breaker 2 poles I=6 A
SHGVA-VA -2-10 Automatic circuit breaker 2 poles I=10 A
SHGVA-VA -2-16 Automatic circuit breaker 2 poles I=16 A
SHGVA-VA -2-20 Automatic circuit breaker 2 poles I=20 A
SHGVA-VA -2-25 Automatic circuit breaker 2 poles I=25 A
SHGVA-VA -2-32 Automatic circuit breaker 2 poles I=32 A
SHGVA-VA -2-40 Automatic circuit breaker 2 poles I=40 A
SHGVA-VA -2-63 Automatic circuit breaker 2 poles I=63 A
SHGVA-VA -2-80 Automatic circuit breaker 2 poles I=80 A
SHGVA-VA -2-100 Automatic circuit breaker 2 poles I=100 A
SHGVA-VA-2-125 Automatic circuit breaker 2 poles I=125 A
SHGVA-VA -2-160 Automatic circuit breaker 2 poles I=160 A
SHGVA-VA -3-6 Automatic circuit breaker 3 poles I=6 A
SHGVA-VA -3-10 Automatic circuit breaker 3 poles I=10 A
SHGVA-VA -3-16 Automatic circuit breaker 3 poles I=16 A
SHGVA-VA -3-20 Automatic circuit breaker 3 poles I=20 A
SHGVA-VA -3-25 Automatic circuit breaker 3 poles I=25 A
SHGVA-VA -3-32 Automatic circuit breaker 3 poles I=32 A
SHGVA-VA -3-40 Automatic circuit breaker 3 poles I=40 A
SHGVA-VA -3-63 Automatic circuit breaker 3 poles I=63 A
SHGVA-VA -3-80 Automatic circuit breaker 3 poles I=80 A
SHGVA-VA -3-100 Automatic circuit breaker 3 poles I=100 A
SHGVA-VA -3-125 Automatic circuit breaker 3 poles I=125 A
SHGVA-VA -3-160 Automatic circuit breaker 3 poles I=160 A
SHGVA-VA -4-6 Automatic circuit breaker 4 poles I=6 A
SHGVA-VA -4-10 Automatic circuit breaker 4 poles I=10 A
SHGVA-VA -4-16 Automatic circuit breaker 4 poles I=16 A
SHGVA-VA -4-20 Automatic circuit breaker 4 poles I=20 A
SHGVA-VA -4-25 Automatic circuit breaker 4 poles I=25 A
SHGVA-VA -4-32 Automatic circuit breaker 4 poles I=32 A
SHGVA-VA -4-40 Automatic circuit breaker 4 poles I=40 A
SHGVA-VA -4-63 Automatic circuit breaker 4 poles I=63 A
SHGVA-VA -4-80 Automatic circuit breaker 4 poles I=80 A
SHGVA-VA -4-100 Automatic circuit breaker 4 poles I=100 A
SHGVA-VA -4-125 Automatic circuit breaker 4 poles I=125 A
SHGVA-VA -4-160 Automatic circuit breaker 4 poles I=160 A

Options

Options, accessories and versions
Marking
Painting the outer surface in the color according to the customer's requirements
/RAL (code)
Anti-condensation coating
/AP
Additional contacts (status contact, signal contact)
/DK
Drainage ventilation devices
/DKUV
Marine version
/MORE
Earthquake-resistant design
/MSHK-64
Thermal heating for automation
/OBOGREV
Motor drive for remote control
/PDU
Customer acceptance
/PRIEMKA
Non-explosion-proof design
/PROM
Mining normal design
/RN
Internal thermal insulation
/TEPLOISOLATSIA
Tropical version with insect protection
/TERMITY

3D models

STP models
zip
Download

Additional information

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Model Breakdown
SHGVA-VA - 1X - 2X - 3X 4X / 5X – TU 3400-005-72453807-07
1X - Number of switch poles
2X - Rated current
3X - Number of cable glands
4X - Type of cable glands
5X - Options, accessories and versions

Order example: SHGVA-VA-2-16-2KNV2 -TU 3400-005-72453807-07
SHGVA-VA device, equipped with:
- 2-pole automatic switch for 16 A with a control handle
- 2 cable glands for unarmored cable KNV2

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more