Saint Petersburg
Head office and production site
Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Ex db IIC Gb U
Ex tb IIIC Db U
Ex db I Mb U (for stainless steel enclosure)| Type | Appearance | Description | Thread | Material, applicability |
Weight, kg |
| RGV01 | ![]() |
![]() |
M20x1.5 | Switch blade - aluminum; shaft - stainless steel. Cam switches. Fixed installation depth. Contact group connection 25-63 A | 0,1 |
| RGVN01 | ![]() |
![]() |
M20x1.5 | Switch flag, stainless steel shaft. Cam switches. Fixed installation depth. Contact group connection 25-63 A | 0,1 |
| RGV05 | ![]() |
![]() |
M16x1.5 | The switch flag is aluminum; the shaft is stainless steel. Automatic motor protection switches. They have a cuttable stem (depth adjustment). They are designed for installation on circuit breakers with a rotary handle. Tested on products from Schneider, ABB, Siemens, and EATON. | 0,2 |
| RGVN05 | ![]() |
![]() |
M16x1.5 | Switch flag, stainless steel shaft. Automatic motor protection switches. Features a cuttable stem (depth adjustment). Mounts on circuit breakers with a rotary handle. Tested on Schneider, ABB, Siemens, and EATON products. | 0,2 |
| RGV08 | ![]() |
![]() |
M20x1.5 | Switch flag - aluminum; shaft - stainless steel. Automatic circuit breakers in a cast case. Features a cuttable stem (depth adjustment). Installation on molded case circuit breakers (up to 250 A). Tested on Schneider, ABB, and IEK products. An additional bracket can be installed for compatibility with circuit breakers up to 630 A. | 0,3 |
| RGVN08 | ![]() |
![]() |
M20x1.5 | Switch flag, stainless steel shaft. Automatic circuit breakers in a cast case. Features a cuttable stem (depth adjustment). Installation on molded case circuit breakers (up to 250 A). Tested on Schneider, ABB, and IEK products. An additional bracket can be installed for compatibility with circuit breakers up to 630 A. | 0,3 |
| RGV09 | ![]() |
![]() |
M16x1.5 | Switch flag - aluminum; shaft - stainless steel. Modular circuit breakers up to 120 A. Features a cuttable stem (depth adjustment). Tested on Schneider, ABB, and IEK products. Not compatible with some circuit breakers due to the switch flag geometry (some Siemens, TDM, and Legrand series). | 0,2 |
| RGVN09 | ![]() |
![]() |
M16x1.5 | Switch flag, stainless steel shaft. Modular circuit breakers up to 120 A. Features a cuttable stem (depth adjustment). Tested on Schneider, ABB, and IEK products. Not compatible with some circuit breakers due to the switch flag geometry (some Siemens, TDM, and Legrand series). | 0,2 |
| RGV11 | ![]() |
![]() |
M16x1.5 | Switch flag - aluminum; shaft - stainless steel. Modular circuit breakers, side mounting. Fixed installation depth. Primarily used in SHGVA-VA. Installation of an additional bracket is possible for compatibility with circuit breakers up to 120 A. | 0,1 |
| RGVN11 | ![]() |
![]() |
M16x1.5 | Switch flag, stainless steel shaft. Modular circuit breakers, side mounting. Fixed installation depth. Primarily used in SHGVA-VA. An additional bracket can be installed for compatibility with circuit breakers up to 120 A. | 0,1 |
| RGV13 | ![]() |
![]() |
M16x1.5 | Switch flag - aluminum; shaft - stainless steel. Modular circuit breakers up to 63 A. Analogous to RGV(N)09 for tighter installation. Suitable for use with 1- and 2-pole circuit breakers. | 0,2 |
| RGVH13 | ![]() |
![]() |
M16x1.5 | Switch flag, stainless steel shaft. Modular circuit breakers up to 63 A. Analogous to RGV(N)09 for tighter installation. Suitable for use with single- and double-pole circuit breakers. | 0,2 |
| M698 | M698/1 | M698/2 | M698/3 |
![]() |
![]() |
![]() |
![]() |
| Switch designation* |
Nom. current, A | Circuit diagram | Handle position | Description |
| RGV...+PG1X10 | 10 | ![]() |
![]() |
Start-stop command for spring return switches in B from both A and C, with locking in B |
| RGV...+PG1R10 | 10 | ![]() |
![]() |
Start-stop command switches with spring return from A to B and latching position in locking C |
| RGV...+PG2R10 | 10 | ![]() |
||
| RGV...+PG1Z10 | 10 | ![]() |
![]() |
A switch with 2 locking positions. Serves to switch control from manual to automatic. |
| RGV...+PG2Z10 | 10 | ![]() |
||
| RGV...+PG3Z10 | 10 | ![]() |
||
| RGV...+PG1I10 | 10 | ![]() |
![]() |
Switch |
| RGV...+PG1I16 | 16 | |||
| RGV...+PG1I32 | 32 | |||
| RGV...+PG1I40 | 40 | |||
| RGV...+PG1I63 | 63 | |||
| RGV...+PG2I10 | 10 | ![]() |
||
| RGV...+PG2I16 | 16 | |||
| RGV...+PG2I32 | 32 | |||
| RGV...+PG2I40 | 40 | |||
| RGV...+PG2I63 | 63 | |||
| RGV...+PG3I10 | 10 | ![]() |
||
| RGV...+PG3I16 | 16 | |||
| RGV...+PG3I32 | 32 | |||
| RGV...+PG3I40 | 40 | |||
| RGV...+PG3I63 | 63 | |||
| RGV...+PG4I10 | 10 | ![]() |
||
| RGV...+PG4I16 | 16 | |||
| RGV...+PG4I32 | 32 | |||
| RGV...+PG4I40 | 40 | |||
| RGV...+PG4I63 | 63 | |||
| RGV...+PG1S10 | 10 | ![]() |
![]() |
Switch with 3 locking positions, lockable in the center position |
| RGV...+PG2S10 | 10 | ![]() |
||
| RGV...+PG3S10 | 10 | ![]() |
||
| RGV...+PG1V10 | 10 | ![]() |
![]() |
3-position switch lockable in the center position with spring return to position B |
| RGV...+PG2V10 | 10 | ![]() |
||
| RGV...+PG1U10 | 10 | ![]() |
![]() |
5- position reversible with handle lockable in positions A, B, C with spring return from D to A and from E to C, lockable in B |
| RGV...+PG1M10 | 10 | ![]() |
![]() |
Start command for switches with spring return of the handle to position A |
Drag files here
CAD " GORELTEX ", questionnaires, necessary documents
Example: RGVN11/M16
Head office and production site
Sales office
Sales office
Sales office and production site
Sales office
Sales office