Explosion-proof boxes SHORVA made of aluminum alloy

Product Description

SHORVA is an explosion-proof terminal box with Ex d protection type made of aluminum. It is used for switching, distributing, and connecting electrical circuits in hazardous areas, including environments containing acetylene. The explosion-proof enclosure reliably contains any spark or explosion within the enclosure, preventing ignition of the external environment. It ensures easy installation and maintenance.

Advantages

  • Acetylene certified for extended use in the most hazardous areas
  • Die casting guarantees impeccable shape accuracy, free of internal stress and voids, as well as high homogeneity of the metal structure.
  • The aluminum housing shell combines exceptional mechanical strength, corrosion resistance and efficient heat dissipation.
  • SHORVA terminal boxes are included in the register of Russian industrial products.

Frequently bought together

Compliance with standards

GOST R IEC 60079-0-2011
GOST 14254-96 (IEC 529-89)
GOST 30852.0-2002 (IEC 60079-0:1998)
GOST 30852.1-2002 (IEC 60079-1:1998)
GOST 30852.10-2002 (IEC 60079-11:1999)
GOST 30852.20-2002
TR CU 012/2011
GOST IEC 61241-1-1-2011
GOST 24754-2013
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
GOST 12.2.007.0-75. Occupational Safety Standards
GOST R IEC 60079-31-2010

Certificates

Markings

Explosion protection marking
1Ex db IIC T6...T4 Gb
1Ex db ib IIC T6...T4 Gb
Ex tb IIIC 85°С...T135°С Db

Housing (EX component)Box (EX component):
Ex db IIC Gb U
Ex tb IIIC Db U
Marking of mining equipment
RN1/RN2
Degree of protection
IP66/IP67/IP68
IK10
Installation
Category II for gas subgroups IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust atmospheres containing volatile particles, non-conductive and conductive dust;
Underground workings that are not hazardous for gas (methane) and coal dust;
Facilities supervised by RMRS

Technical data

Ambient temperature, °C
-60...+40 (T6/T85°C)
-60...+60 (T5/T100°C)
-60...+85 (T4/T135°C)
-60…+85 (for PH2 version)
-60...+150 (for Ex-components)
Maximum voltage, V
~1000 / ⎓600
Maximum current, A
800
Placement of cable glands
According to customer specifications
Grounding
2 ground cluminaires (internal and external) made of stainless steel
Cover fastening
Threaded connection
Mounting inside the case
2 or 4 mounting posts for panel mounting
Coating
Polymer-epoxy paint with antistatic properties, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Sealing
Silicone rubber (in the lid groove), silicone seal
Material
Aluminum alloy with alloying modifiers
Housing fastening
2 or 4 external mounting points
Protection class against electric shock
I
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

Overall dimensions of explosion-proof boxes of the SHORVA type (explosion-proof enclosures)

Overall dimensions of SHORVA boxes
Box size Dimensions, mm Weight, kg
External Internal Fastening
A B C a b c Ød Ød1 s E F ØG
SHORVA121211 120 120 115 94 94 74 82 M95x2 13 100 145 10 1,9
SHORVA131313 130 130 134 106 106 94 116 M130x2 12 111 138 8 2,3
SHORVA151512 151 151 125 124 124 84 116 M130x2 13 126 174 11 2,8
SHORVA171712 175 175 129,5 146 146 89 137 M150x2 14 150 195 11 3,6
SHORVA232316 235 235 164 203 203 117 185 M200x2 14 196 267 14 7,4
SHORVA272721 276,5 276,5 218 248 248 152 232 M250x3 14 236 316 14 11,4
SHORVA363626 361,5 361,5 264,5 329 329 201,5 279 M325x3 15,5 318 395 14 23
SHORVA424229 429,5 429,5 291 395,5 395,5 216 330 M390x4 16,5 390 480 14 35,6

Mounting panel
Mounting panel

Overall dimensions of mounting panels
Name* Dimensions, mm Weight, kg
A B a b Aluminum Stainless steel
ЩА1212X 80 80 60 48 0,03 0,1
ЩА1313X 100 100 80 60 0,05 0,16
ЩА1515X 100 100 80 60 0,05 0,16
ЩА1717X 115 115 90 90 0,07 0,21
ЩА2323X 150 150 130 130 0,12 0,36
ЩА2727X 200 200 158 158 0,22 0,63
ЩА3636X 240 240 200 200 0,3
ЩА4242X 270 270 230 230 0,39 1,15

*X - material code: A - aluminum, H - stainless steel.

Options

Options, accessories and versions
Marking
Degree of protection against external influences IP68
/IP68
Painting the outer surface in the color according to the customer's requirements
/RAL (code)
Aluminum alloy mounting panel
/ALP
Anti-condensation coating
/AP
Ventilation device for moisture removal
/VKU
Drainage ventilation devices
/DKUV
Conservation
/KONSERVATSIA
Design for operation at nuclear power plants
/MALAYA TECH
Marking of terminal cluminaires according to the customer's diagram
/MARK
Marine version
/MORE
Earthquake-resistant design
/MSHK-64
A plate with the customer's inscription
/NADPIS "_"
Stainless steel mounting plate
/NP
Thermal heating for automation
/OBOGREV
Compliance with fire safety requirements
/POZHAR
Customer acceptance
/PRIEMKA
Non-explosion-proof design
/PROM
River execution
/RIVER
Mining normal design
/RN
The presence of jumpers between terminal cluminaires according to the customer's diagram
/SCHEME
Internal thermal insulation
/TEPLOISOLATSIA
Tropical version with insect protection
/TERMITY
Internal grounding busbar
/TIRE Z
Neutral busbar
/TIRE N
Phase buses
/TIRE F
Device for combining cable screens
/SCREEN

Note: For the /BUS Z and /BUS H , the default configuration is buses with 2 x 16 mm2holes and a row of 6 mm2 holes( the number depends on the bus length). Busbars with different hole diameters can be installed upon agreement with the customer.

3D models

STP models
zip
Download

Additional information

The maximum recommended number of cable glands on the sides of the SHORVA boxes
Box size Thread size
01 1 2 3 4 5 6 7 8
Thread type NPT/M according to GOST 24705
NPT/M NPT/M NPT/M NPT/M NPT/M NPT/M NPT/M NPT/M NPT/M
SHORVA121211 3/2 2/2 2/2 1/1 1/1 - - - -
SHORVA151512 5/5 4/4 3/3 2/2 2/2 1/1 - - -
SHORVA171712 6/6 5/5 3/3 2/2 2/2 2/2 1/1 - -
SHORVA232316 8/8 8/8 7/8 4/4 3/3 2/2 2/2 2/2 -
SHORVA272721 14/14 14/14 11/11 8/8 6/6 4/4 3/3 2/2 2/2
SHORVA363626 18/18 18/18 14/14 10/10 7/7 5/5 4/4 3/3 2/2
SHORVA424229 22/22 22/22 18/18 11/12 10/10 8/8 5/5 3/3 3/3
Maximum permissible number of installed WDU terminals (excluding installation of cable glands)
Box size Maximum number of terminals (maximum number of terminals in one row)/nominal wire cross-section, mm2
2,5 4 6 10 16 35 50N 70N/35
SHORVA121211 6 5 4 3 - - - -
SHORVA131313 8 6 5 4 3 2 - -
SHORVA151512 16 14 10 8 7 5 - -
SHORVA171712 19 16 12 10 8 6 5 -
SHORVA232316 37(26) 32(22) 17 13 11 8 7 6
SHORVA272721 49(36) 42(30) 32(23) 26(18) 22(15) 14(11) 10 9
SHORVA363626 102 (46) 84 (38) 58 (29) 37 (23) 30 (19) 22 (14) 18 (12) 10
SHORVA424229 114(50) 96(42) 72(32) 57(25) 42(21) 32(16) 22(13) 14

LOCATION OF EQUIPMENT INSIDE THE SHORVA BOXES

Typical electrical components installed in boxes include terminal cluminaires, circuit breakers, residual-current devices (RCDs), residual-current circuit breakers, contactors, circuit breakers, fuses, ballast chokes, transformers, relays and timers, starters, IT components, remote-controlled switches, active/passive spark-proof barriers, and Ni-Cd batteries. The electrical equipment and components supplied with the boxes are from leading manufacturers. Other equipment options are available upon special request.

Explosion-proof boxes of the SHORVA type (explosion-proof enclosures) Explosion-proof boxes of the SHORVA type (explosion-proof enclosures)
Explosion-proof boxes of the SHORVA type (explosion-proof enclosures)

EXPLOSION-PROOF FRAMES IIGb / IIIDb FOR MODULAR DESIGN

The use of a module of two or more explosion-proof SHORVA boxes allows solving problems where dimensions are required that exceed the maximum produced size of SHORVA explosion-proof boxes.

When designing cabinets, situations arise where the dimensions of the existing enclosures are insufficient to accommodate the equipment. In this case, the cabinet can be divided into individual modules, connected either by metal sleeves or conduit. Using relatively small modules reduces the cabinet's dimensions, weight, and cost.

Furthermore, the large surface area allows for accessible cable glands, significantly simplifying installation. Modular cabinets are mounted on a frame /FRAME/ made of galvanized steel (cold or hot-dip galvanized), or, upon request, stainless steel.

The frames are manufactured for wall or floor mounting and are classified as friction-insincerely safe non-electrical equipment with explosion protection levels IIGb and IIIDb.

The use of a module of two or more explosion-proof SHORVA boxes allows solving problems where dimensions are required that exceed the maximum produced size of SHORVA explosion-proof boxes. The use of a module of two or more explosion-proof SHORVA boxes allows solving problems where dimensions are required that exceed the maximum produced size of SHORVA explosion-proof boxes.

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Contact Sales Department Download questionnaire Configure in CAD
Model Breakdown
SHORVA 1X ( 2X 3X - 2X 3X ) - 4X 5X ( 6X ) - 4X 5X ( 6X ) / 7X – TU 27.33.13-033-72453807-2017
1X - Size Code
2X - Number of terminal cluminaires
3X - Terminal cluminaire type
4X - Number of cable glands
5X - Cable entry type
6X - Input side Sides of cable entry locations
7X - Options, accessories and versions

Example: SHORVA171712 (40C2 - 10C16) - 3KNV1N(B) - 2KNV4N(G) - TU 27.33.13-033-72453807-2017

If you have difficulty choosing the box size based on the required characteristics, put the letter X instead of numbers after the box name.

Example: SHORVA X (40C2 - 10C16) - 3KNV1N(B) - 2KNV4N(G) - TU 27.33.13-033-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Read more
193149, Russia, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1

Moscow

Sales office

Read more
123112, Russia, Moscow, Presnenskaya embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15

Kazan

Sales office

Read more
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110