Explosion-proof boxes SHORVA...-O with a window

Product Description

The SHORVA…-O is an explosion-proof terminal box with Ex d protection rating, made of aluminum alloy with alloying modifiers. It is used for switching, distributing, and connecting electrical circuits in hazardous areas, including environments containing acetylene. The explosion-proof enclosure reliably contains any spark or explosion within the enclosure, preventing ignition of the external environment. It ensures easy installation and maintenance.

Advantages

  • Acetylene certified for extended use in the most hazardous areas
  • Die casting guarantees impeccable shape accuracy, free of internal stress and voids, as well as high homogeneity of the metal structure.
  • The aluminum housing shell combines exceptional mechanical strength, corrosion resistance and efficient heat dissipation
  • Visual monitoring of equipment status thanks to impact-resistant tempered glass

Frequently bought together

Compliance with standards

GOST R IEC 60079-0-2011
GOST 14254-96 (IEC 529-89)
GOST 30852.0-2002 (IEC 60079-0:1998)
GOST 30852.1-2002 (IEC 60079-1:1998)
GOST 30852.10-2002 (IEC 60079-11:1999)
GOST 30852.20-2002
TR CU 012/2011
GOST IEC 61241-1-1-2011
GOST 24754-2013
Chapter 7.3 of the Electrical Installation Code
GOST R IEC 60079-31-2010
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
GOST 12.2.007.0-75. Occupational Safety Standards

Certificates

Markings

Explosion protection marking
1Ex db IIC T6...T4 Gb
1Ex db ib IIC T6...T4 Gb
Ex tb IIIC 85°С...T135°С Db

Housing (EX component)Box (EX component):
Ex db IIC Gb U
Ex tb IIIC Db U
Marking of mining equipment
RN1/RN2
Degree of protection
IP66/IP67/IP68
IK08
Installation
Category II for gas subgroups IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust atmospheres containing volatile particles, non-conductive and conductive dust;
Underground workings that are not hazardous for gas (methane) and coal dust;
Facilities supervised by RMRS

Technical data

Ambient temperature, °C
-60...+40 (T6/T85°C)
-60...+60 (T5/T100°C)
-60...+85 (T4/T135°C)
-60…+85 (for PH2 version)
-60...+150 (for Ex-components)
Maximum voltage, V
~1000 / ⎓500
Maximum current, A
800
Placement of cable glands
According to customer specifications
Grounding
2 ground cluminaires (internal and external) made of stainless steel
Cover fastening
Threaded connection
Mounting inside the case
2 or 4 mounting posts for panel mounting
Coating
Polymer-epoxy paint with antistatic properties, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Sealing
Silicone rubber (in the lid groove), silicone seal
Material
Aluminum alloy with alloying modifiers. Window - impact-resistant, heat-resistant glass.
Housing fastening
2 or 4 external mounting points
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

Overall dimensions of explosion-proof boxes of the SHORVA…-O type with a window (explosion-proof enclosures)

Overall dimensions of the SHORVA…-O boxes
Box size Dimensions, mm Weight, kg
External Internal Window Fastening
A B C a b c Ød Ød1 s v ØL E F ØG
SHORVA131313-O09 130 130 134 106 106 94 116 M130x2 12 12 90 100 145 10 2,5
SHORVA151512-O09 151 151 125 124 124 76 93 M130x2 13 12 90 126 174 11 3,1
SHORVA171712-O09 175 175 150 146 146 102 137 M150x2 14 12 90 150 195 11 4,1
SHORVA232316-O14 235 235 155 203 203 98,5 161 M200x3 14 12 140 196 267 14 8,3
SHORVA272721-O18 276.5 276.5 218 248 248 146.5 203 M250x3 14 15 180 236 316 14 13

Mounting panel
Mounting panel

Overall dimensions of mounting panels
Name* Dimensions, mm Weight, kg
A B a b Aluminum Stainless steel
ЩА1313X 100 100 80 60 0,05 0,16
ЩА1515X 100 100 80 60 0,05 0,16
ЩА1717X 115 115 90 90 0,07 0,21
ЩА2323X 150 150 130 130 0,12 0,36
ЩА2727X 200 200 158 158 0,22 0,63

*X - material code: A - aluminum, H - stainless steel.

Options

Options, accessories and versions
Marking
Degree of protection against external influences IP68
/IP68
Painting the outer surface in the color according to the customer's requirements
/RAL (code)
Aluminum alloy mounting panel
/ALP
Anti-condensation coating
/AP
Ventilation device for moisture removal
/VKU
Drainage ventilation devices
/DKUV
Design for operation at nuclear power plants
/MALAYA TECH
Marking of terminal cluminaires according to the customer's diagram
/MARK
Marine version
/MORE
Earthquake-resistant design
/MSHK-64
A plate with the customer's inscription
/NADPIS "_"
Stainless steel mounting plate
/NP
Thermal heating for automation
/OBOGREV
Customer acceptance
/PRIEMKA
Cooling radiator
/RADIATOR
River execution
/RIVER
Mining normal design
/RN
The presence of jumpers between terminal cluminaires according to the customer's diagram
/SCHEME
Internal thermal insulation
/TEPLOISOLATSIA
Tropical version with insect protection
/TERMITY
Internal grounding busbar
/TIRE Z
Neutral busbar
/TIRE N
Phase buses
/TIRE F
Device for combining cable screens
/SCREEN

Note: For the /BUS Z and /BUS H , the default configuration is buses with 2 x 16 mm2holes and a row of 6 mm2 holes( the number depends on the bus length). Busbars with different hole diameters can be installed upon agreement with the customer.

3D models

STP models
zip
Download

Additional information

Maximum number of cable glands on the sides of SHORVA boxes
Box size On one side
Cable entry thread type
1/2"
20x1.5
3/4"
25x1.5
1"
32x1.5
1 1/4"
40x1.5
1 1/2"
50x1.5
2"
63x1.5
2 1/2"
75x1.5
3"
85x2
    4"   
SHORVA151512-O09
5 3 2 2 2 1 - - -
SHORVA171712-O09
8 6 5 3 2 2 2 - -
SHORVA232316-O14
15 12 8 6 6 3 2 2 1
SHORVA272721-O18
21 14 12 10 9 4 3 3 2

EXPLOSION-PROOF FRAMES IIGb / IIIDb FOR MODULAR DESIGN

The use of a module of two or more explosion-proof boxes SHORVA...-O allows solving problems where dimensions are required that exceed the maximum produced size of explosion-proof boxes SHORVA...-O.

When designing cabinets, situations arise where the dimensions of the existing enclosures are insufficient to accommodate the equipment. In this case, the cabinet can be divided into individual modules, connected either by metal sleeves or conduit. Using relatively small modules reduces the cabinet's dimensions, weight, and cost.

Furthermore, the large surface area allows for accessible cable glands, significantly simplifying installation. Modular cabinets are mounted on a frame /FRAME/ made of galvanized steel (cold or hot-dip galvanized), or, upon request, stainless steel.

The frames are manufactured for wall or floor mounting and are classified as friction-insincerely safe non-electrical equipment with explosion protection levels IIGb and IIIDb.

Explosion-proof boxes of the SHORVA…-O type with a window (explosion-proof enclosures) on a frame Explosion-proof boxes of the SHORVA…-O type with a window (explosion-proof enclosures) on a frame

LOCATION OF EQUIPMENT INSIDE THE SHORVA BOXES...-O

Typical electrical components installed in the boxes include instrumentation and control devices, as well as any visual control equipment, including monitors and displays, video cameras, IT components, relays and timers, terminal cluminaires, fuses, etc. The electrical equipment and components supplied with the boxes are manufactured by leading manufacturers. Other equipment options can be supplied upon special request.

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Contact Sales Department Download questionnaire Configure in CAD
Model Breakdown
SHORVA 1X -O 2X - 3X 4X ( 5X ) - 3X 4X ( 5X ) / 6X – TU 27.33.13-033-72453807-2017
1X - Case size code
2X - Window size code
3X - Number of cable glands
4X - Cable entry type
5X - Input location side Sides of cable entry locations
6X - Options, accessories and versions

Example: SHORVA171712-O09-3KNV1N(B)-2KNV4N(G)-TU 27.33.13-033-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more