Explosion-proof boxes ЩОРВ-НТ made of stainless steel

Product Description

The SHORV-NT is an explosion-proof terminal box with Ex d protection rating, made of stainless steel. It is used for switching, distributing, and connecting electrical circuits in hazardous areas. The explosion-proof enclosure reliably contains any spark or explosion within the enclosure, preventing ignition of the external environment. It ensures easy installation and maintenance.

Advantages

  • Certified equipment ensuring safety and uninterrupted operation.
  • The body is made of stainless steel, resistant to aggressive environments, alkalis, sulfuric and hydrochloric acids.
  • Double-sided electrochemical polishing ensures a durable and aesthetic appearance.
  • Certified for food, oil and gas, chemical, marine and mining applications.
  • Terminal boxes SHORV-NT are included in the register of Russian industrial products.

Frequently bought together

Markings

Explosion protection marking
1Ex db IIB+H2 T6...T4 Gb
1Ex db IIC T6...T4 Gb X
1Ex db ib IIB+H2 T6...T4 Gb
1Ex db ib IIC T6...T4 Gb X
Ex tb IIIC T85°...T135°С Db

Housing (EX component)Box (EX component):
Ex db IIB+H2 Gb U
Ex db IIC Gb U* (for SHORV-NT101008for SHORV-NT101008, *prohibited for use in explosive mixtures of acetylene with airforbidden to use in explosive mixtures of acetylene with air)
Ex tb IIIC Db U
Marking of mining equipment
PB Ex db I Mb
PB Ex ib I Mb
PB Ex db ib I Mb
PO Ex ia I Ma
RN1/RN2

Housing (EX component)Box (EX component):
Ex db I Mb U
Degree of protection
IP66/IP67/IP68
IK10
Installation
Category I for firedamp and dust;
Category II for gas subgroups IIA, IIB, IIB+H2,IIC (except acetylene), zones 1, 2;
Category III for dust, explosive dust atmospheres containing volatile particles, non-conductive and conductive dust;
Underground workings hazardous due to gas (methane) and coal dust;
Facilities supervised by RMRS

Technical data

Ambient temperature, °C
-60...+40 (T6/T85°C)
-60...+60 (T5/T4/T100°C/T135°C)*
-60…+60 (for mine explosion-proof and mine normal designs)
-60...+150 (for Ex-components)

*depending on the box configuration
Maximum voltage, V
~1000 / ⎓600
Maximum current, A
800
Placement of cable glands
According to customer specifications
Grounding
2 ground cluminaires (internal and external) made of stainless steel
Cover fastening
Removable hinged lid
Mounting inside the case
4 posts for mounting the mounting panel
Surface
Electrochemical polishing (external and internal)
Sealing
Silicone rubber (in the lid groove)
Material
Stainless steel sheet grade 08Kh18N10 according to GOST 5632-2014 (AISI 304).
Stainless steel grade 08x17M13M2T according to GOST 5632-2014 (AISI 316), option /316
Housing fastening
4 external mounting points
Protection class against electric shock
I
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

Overall dimensions of the SHORV-NT boxes*
Box size Dimensions, mm Weight, kg
External Internal Fastening with staples
A IN WITH a b c s D E F
SHORVA-NT282218 285 226 180 187 128 132 12 160 216 9 19,4
SHORVA-NT312012 317 211 127 219 113 79 12 160 201 9 17,5
SHORVA-NT322212 327 227 125 229 129 77 12 230 225 9 19
SHORVA-NT322220 327 227 208 229 129 160 12 230 240 9 23,9
SHORVA-NT393113 391 319 138 294 221 90 12 290 305 11 31,6
SHORVA-NT393127 391 319 279 294 221 231 12 290 320 11 43,5
SHORVA-NT452512 451 250 125 354 153 77 12 350 246 11 28,2
SHORVA-NT452521 451 250 216 354 153 168 12 350 261 11 35,9
SHORVA-NT453719 457 372 197 354 269 141 16 350 345 11 57,7
SHORVA-NT453729 457 372 308 354 269 252 16 350 360 11 69,2
SHORVA-NT584019 589 409 197 484 304 141 16 360 391 11 79,7
SHORVA-NT584028 589 409 295 484 304 239 16 360 406 11 92,6
SHORVA-NT694923 693 495 229 568 370 159 16 550 455 14 119
SHORVA-NT694933 693 495 347 568 370 277 16 400 470 14 134,1
SHORVA-NT765636 767 567 364,5 637 437 290 20 600 540 16 194
SHORVA-NT906834 900 680 347,5 770 550 263 10 680 664 20 267
SHORVA-NT906845 900 680 461 770 550 377 10 680 650 20 298
SHORVA-NT1035839 1030 580 403 900 450 319 10 790 550 20 275

* - it is possible to manufacture cases of non-standard sizes.

Overall dimensions of mounting panels for SHORV-NT boxes
Name of the corps Name Stainless steel Aluminum alloy
Length, mm Width, mm Thickness, mm Weight, kg Length, mm Width, mm Thickness, mm Weight, kg
SHORVA-NT282218 Щ2822Х 170 110 2 0,3 170 110 2 0.1
SHORVA-NT312012 Щ2818Х 206 100 2 0,3 206 100 2 0,1
SHORV-NT322212
SHORV-NT322220
Щ3020Х 220 120 2 0,4 220 120 2 0,1
Щ3020Х/ТЕRМО 200 100 2 0,3 200 100 2 0,1
SHORV-NT393113
SHORV-NT393127
Щ3628Х 280 200 2 0,9 260 180 2 0,3
Щ3628Х/TERMO 260 180 2 0,7 260 180 2 0,2
SHORV-NT452512
SHORV-NT452521
Щ4222Х 340 140 2 0,8 340 140 2 0,2
Щ4222Х/TERMO 320 120 2 0,6 320 120 2 0,2
SHORV-NT453719
SHORV-NT453729
Щ4232Н 340 240 2 1,3 340 240 2 0,4
Щ4232Н/ТЕRМО 320 220 2 1,1 320 220 2 0,4
SHORV-NT584019
SHORV-NT584028
Щ5739Н 456 276 2 2 456 276 3 1
Щ5739Н/ТЕRМО 455 275 2 2 460 280 3 1
SHORV-NT694923
SHORV-NT694933
Щ6545Н 540 340 2 2,9 532 332 3 1,4
Щ6545Н/TERMO 520 320 2 2,6 520 320 3 1,3
SHORVA-NT765636 Щ7252X* 597 397 2 3,8 597 397 3 1,9
SHORV-NT906834
SHORV-NT906845
Щ8967Х* 720 500 3 8 720 500 3 2,9
SHORVA-NT1035839 Щ10458Х* 850 400 3 7,6 850 400 3 2,7

* - when heating the case, a standard mounting panel is used.

Options

Options, accessories and versions
Marking
Stainless steel grade 08x17M13M2T according to GOST 5632-2014 (AISI 316)
/316
Degree of protection against external influences IP67
/IP67
Degree of protection against external influences IP68
/IP68
Painting the outer surface in the color according to the customer's requirements
/RAL (code)
Ventilation device for moisture removal
/VKU
Drainage ventilation devices
/DKUV
Conservation
/KONSERVATSIA
Marine version
/MORE
Captive cover mounting bolts
/NBK
Stainless steel mounting plate
/NP
Fixing the lid on hinges
/LOOP
Bolt with seal
/SEAL
Compliance with fire safety requirements
/POZHAR
Non-explosion-proof design
/PROM
River execution
/RIVER
Internal thermal insulation
/TEPLOISOLATSIA
Design for minimum operating temperature of -75°C
/HOLOD

3D models

STP models
zip
Download

Additional information

The maximum number of openings in the cover of the terminal box housings of the ЩОРВ-НТ series
Case size Metric thread
02 01 1 2 3 4
SHORVA-NT282218 14 14 12 9 6 6
SHORVA-NT312012 15 14 14 10 8 6
SHORV-NT322212
SHORV-NT322220
16 15 14 8 8 6
SHORV-NT393113
SHORV-NT393127
35 35 26 24 17 15
SHORV-NT452512
SHORV-NT452521
31 27 24 20 14 10
SHORV-NT453719
SHORV-NT453729
48 48 44 29 24 20
SHORV-NT584019
SHORV-NT584028
84 77 60 51 44 28
SHORV-NT694923
SHORV-NT694933
112 112 88 73 54 39
SHORVA-NT765636 161 161 138 106 81 64
SHORV-NT906834
SHORV-NT906845
225 225 216 157 110 86
SHORVA-NT1035839 237 237 195 158 117 96
Maximum number of openings in the housing of the terminal boxes ЩОРВ-НТ on the A/B side
Box size Metric thread
02 01 1 2 3 4 5 6 7 8 10
SHORVA-NT282218 8(9)/6 8(9)/6 8(9)/6 6/4 5/4 3/2 2/1 2/1 1/1 1/1 1/0
SHORVA-NT312012 8(7)/5 8(7)/4 8(7)/4 5/3 3/2 3/1 2(1)/1 2(1)/1 - - -
SHORVA-NT322212 8(7)/4 8(7)/4 7(6)/3 5/2 3/2 3/1 2/1 - - - -
SHORVA-NT322220 14/6 14/6 13/6 12(11)/5 7(6)/4 6/2 4(3)/2 3/1 2/1 2(1)/1 1/1
SHORVA-NT393113 11/8 11(10)/6 9/6 8/4 5/3 4/3 3/2 3(2)/2 - - -
SHORVA-NT393127 28/20 28/20 25/20 21(20)/15 15(14)/10 10/8 8/6 6/4 4/4 2/2 2/1
SHORVA-NT452512 13(12)/5 13(12)/5 11/4 8(7)/3 5/2 4/2 4/1 - - - -
SHORVA-NT452521 26(24)/9 26(24)/9 26(24)/9 18/7 14(13)/5 9(8)/4 8(7)/2 6(5)/1 3/1 3/1 2/1
SHORVA-NT453719 20/15 20/15 18/14 16(15)/10 10/7 7/6 6(5)/4 4/3 3/2 2/2 2/1
SHORVA-NT453729 35/27 36/27 36(35)/27 28(27)/20 19(18)/16 15/12 12(11)/8 8/6 6/4 3/2 2/2
SHORVA-NT584019 28(27)/17 28(27)/17 25(24)/17 24(23)/13 13(12)/8 11/7 8(7)/6 5/3 4/2 3/2 3/2
SHORVA-NT584028 45/30 50(48)/30 45/28 38(36)/22 25/15 18/12 14/9 10/6 8/5 6/4 3/2
SHORVA-NT694923 38(35)/24 38(35)/24 31/20 28/18 18/12 14/9 12/8 8/5 5/3 4/3 4/2
SHORVA-NT694933 60/40 56(55)/40 55/40 45(44)/30 32/21 20/15 16/12 10/8 8/6 8/6 4/3(2)
SHORVA-NT765636 60/40 60/40 60/40 46/29 36(34)/24 24(23)/15 21(20)/14 14/10 10/6 7(6)/4 4/3
SHORVA-NT906834 60/42 60/42 60/42 52(51)/36 33/23 29(28)/20 19/13 15/10 12/8 6/4 4/3
SHORVA-NT906845 92/66 92/66 92/66 70/51 52/36 36/28 30/20 20/16 16/10 10/4 8/4
SHORVA-NT1035839 100/48 100/48 100/48 78/38 53(52)/25 46(45)/22 30/14 26(24)/12 15/7 11/5 7/3
The maximum number of terminal cluminaires installed in the housing of the terminal box of the ЩОРВ-НТ series
Box size Maximum possible number of installed terminal cluminaires
Nominal cross-section of wire, mm2
1 1,5 2,5 4 6 10 16 25, 35 50 70 95 120 150 185, 240
SHORVA-NT282218 23 23 23 19 14 11 9 7 - - - - - -
SHORVA-NT312012 94 94 64 54 42 17 14 10 9 8 6 - - -
SHORVA-NT322212 94 94 64 54 42 17 14 10 9 8 6 - - -
SHORVA-NT322220 94 94 64 54 42 17 14 10 9 8 6 - - -
SHORVA-NT393113 198 198 88 74 56 46 38 28 19 10 8 9 8 7
SHORVA-NT393127 198 198 88 74 56 46 38 28 19 10 8 9 8 7
SHORVA-NT452512 324 324 168 141 105 87 48 36 24 12 10 - - -
SHORVA-NT452521 324 324 168 141 105 87 48 36 24 12 10 - - -
SHORVA-NT453719 324 324 168 141 108 87 48 36 24 12 10 9 8 7
SHORVA-NT453729 324 324 168 141 108 87 48 36 24 12 10 9 8 7
SHORVA-NT584019 575 575 395 330 204 164 102 75 32 17 15 14 13 11
SHORVA-NT584028 575 575 395 330 204 164 102 75 32 17 15 14 13 11
SHORVA-NT694923 828 828 475 395 305 245 164 120 68 20 18 17 15 13
SHORVA-NT694933 828 828 475 395 305 245 164 120 68 20 18 17 15 13
SHORVA-NT765636 950 950 505 450 325 265 184 128 72 34 30 18 18 15
SHORVA-NT906834 980 980 550 480 348 385 204 132 76 64 36 32 32 19
SHORVA-NT906845 980 980 550 480 348 385 204 132 76 64 36 32 32 19
SHORVA-NT1035839 760 760 620 520 300 240 140 104 76 38 33 26 26 22

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Contact Sales Department Download questionnaire Configure in CAD
Model Breakdown
SHORVA-NT 1X ( 2X 3X - 2X 3X ) - 4X 5X ( 6X ) - 4X 5X ( 6X ) / 7X – TU 27.33.13-033-72453807-2017
1X - Size Code
2X - Number of terminal cluminaires
3X - Terminal cluminaire type
4X - Number of cable glands
5X - Cable entry type
6X - Input side Sides of cable entry locations
7X - Options, accessories and versions

Example: SHORV-NT452521 (40C2 - 10C16) - 5KNV1N(B) - 2KNV4N(G) - TU 27.33.13-033-72453807-2017

If you have difficulty choosing the box size based on the required characteristics, put the letter X instead of numbers after the box name.

Example: SHORV-NT X (40C2 - 10C16) - 5KNV1N(B) - 2KNV4N(G) - TU 27.33.13-033-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more