Saint Petersburg
Head office and production site
Terminal boxes, entry number in the RRPP 10793509
TU 27.33.13-033-72453807-2017
TU 27.12.40-032-72453807-2017
1Ex db IIC T6...T4 Gb
1Ex ia IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db
Ex db IIC Gb U
Ex ia IIC Gb U
Ex e IIC Gb U
Ex ia IIIC Da U
Ex tb IIIC Db UBoxes series KKVA-K

| Box size | Inlet holes F | Lid diameter, mm | H | A1 | Weight, kg |
| KKVA-K90M1 | 4 x M20x1.5 | 90 | 75,5 | 106 | 0,6 |
| KKVA-K90M2 | 4 x M25x1.5 | 0,6 | |||
| KKVA-K90M3 | 4 x M32x1.5 | 0,5 | |||
| KKVA-K144M1 | 4 x M20x1.5 | 144 | 115 | 175 | 2,3 |
| KKVA-K144M2 | 4 x M25x1.5 | 2,2 | |||
| KKVA-K144M3 | 4 x M32x1.5 | 2,1 | |||
| KKVA-K144M4 | 4 x M40x1.5 | 2 | |||
| KKVA-K144M5 | 4 x M50x1.5 | 1,9 | |||
| KKVA-K144M6 | 4 x M63x1.5 | 1,7 |
Boxes series KKVA-KS

| Box size | Inlet holes F | Lid diameter, mm | H | A1 | B | X | Weight, kg |
| KKVA-KS90M1 | 4 x M20x1.5 | 90 | 75,5 | 106 | 130 | 109 | 0,7 |
| KKVA-KS90M2 | 4 x M25x1.5 | 0,7 | |||||
| KKVA-KS90M3 | 4 x M32x1.5 | 0,6 | |||||
| KKVA-KS144M1 | 4 x M20x1.5 | 144 | 119 | 175 | 190 | 170 | 2,5 |
| KKVA-KS144M2 | 4 x M25x1.5 | 2,4 | |||||
| KKVA-KS144M3 | 4 x M32x1.5 | 2,3 | |||||
| KKVA-KS144M4 | 4 x M40x1.5 | 2,2 | |||||
| KKVA-KS144M5 | 4 x M50x1.5 | 2,1 | |||||
| KKVA-KS144M6 | 4 x M63x1.5 | 1,9 |
KKVA-TSG series boxes

| Box size | Inlet holes F | Lid diameter, mm | H | A1 | B | C | X | Weight, kg |
| KKVA-TSG90M1 | 3 x M20x1.5 | 90 | 75,5 | 106 | 125 | 121 | 111 | 0,7 |
| KKVA-TSG90M2 | 3 x M25x1.5 | 0,7 | ||||||
| KKVA-TSG90M3 | 3 x M32x1.5 | 0,6 | ||||||
| KKVA-TSG144M1 | 3 x M20x1.5 | 144 | 120 | 175 | 160 | 186 | 130 | 3,4 |
| KKVA-TSG144M2 | 3 x M25x1.5 | 3,3 | ||||||
| KKVA-TSG144M3 | 3 x M32x1.5 | 3,2 | ||||||
| KKVA-TSG144M4 | 3 x M40x1.5 | 3,1 | ||||||
| KKVA-TSG144M5 | 3 x M50x1.5 | 3 | ||||||
| KKVA-TSG144M6 | 3 x M63x1.5 | 2,9 |
| Terminal type | Maximum cross-section of flexible multi-core wire, mm2 | Rated current, A | Maximum voltage, V | Overall dimensions, mm | ||
|---|---|---|---|---|---|---|
| A | B | C | ||||
| AVK 2.5 RD | 2,5 | 24 | 750 | 5 | 44,2 | 44,6 |
| AVK 4 RD | 4 | 32 | 750 | 6 | 44,2 | 44,6 |
| AVK 6 | 6 | 41 | 630 | 8 | 44,2 | 44,6 |
| AVK 10 | 10 | 57 | 630 | 10 | 44,2 | 44,6 |
| AVK 16 | 16 | 76 | 750 | 12 | 52,8 | 58,6 |
| AVK 35 | 35 | 125 | 750 | 16 | 52,8 | 58,6 |
| Frame | Nominal cross-section of wire, mm² | |
|---|---|---|
| 2,5 | 4 | |
| Number of terminals | ||
| KKVA-K90 | 9 | 7 |
| KKVA-K144 | 19 | 16 |
| Frame | Nominal cross-section of wire, mm² | |||||
|---|---|---|---|---|---|---|
| 2,5 | 4 | 6 | 10 | 16 | 35 | |
| Number of terminals | ||||||
| KKVA-K144 | 17 | 14 | 10 | 8 | 7 | 5 |
*The number of terminals is indicated without taking into account the installation of cable glands
Explosion-proof boxes of the KKVA series can be used as input terminal boxes for a wide variety of sensors and devices.
Drag files here
CAD " GORELTEX ", questionnaires, necessary documents

Example: KKVA-K144M2(4WDU6)-KNV2MHK (A)-KOV2MNK (B,G)-VZN2MNK (V)-TU 27.33.13-033-72453807-2017
Head office and production site
Sales office
Sales office
Sales office and production site
Sales office
Sales office