Saint Petersburg
Head office and production site
EAEU N RU D‑RU.RA09.11709/25
1Ex eb IIC T6...T4 Gb
1Ex db eb IIC T6...T4 Gb
1Ex eb mb IIC T6...T4 Gb
1Ex db eb mb IIC T6...T4 Gb
1Ex ia IIC T6...T4 Gb
0Ex ia IIC T6...T4 Ga X
*Size depends on the type of controls and/or indicators installed.
| Case size |
Max. number of controls and indicators on the housing cover ** |
Dimensions, mm | Body weight, kg | ||||||
| external | installation | ||||||||
| A | B | C | X | X1 | Y | ØD | |||
| PKIE111109 | 1 | 112 | 112 | 91 | 94 | - | 94 | 6,3 | 0,8 |
| PKIE171109 | 3 | 172 | 112 | 91 | 154 | - | 94 | 6,3 | 1,1 |
| PKIE141410 | 4 | 149,5 | 149,5 | 107 | 131 | - | 131 | 6,3 | 1,4 |
| PKIE202012 | 6 | 201 | 201 | 129 | 180 | - | 180 | 6,5 | 2,5 |
| PKIE301410 | 8 | 304,5 | 149,5 | 109 | 285 | - | 131 | 6,3 | 2,4 |
| PKIE302314 | 15 | 305 | 231 | 140 | 285 | - | 211 | 6,3 | 3,9 |
| PKIE302318 | 16 | 305 | 231 | 189 | 285 | - | 211 | 6,3 | 4,5 |
| PKIE513321 | 35 | 511 | 336 | 207 | 418 | - | 330 | 9 | 15 |
| PKIE663221 | 45 | 669 | 329 | 207 | 576 | 288 | 332 | 9 | 18,7 |
| PKIE626221 | 95 | 622 | 622 | 208 | 530 | 265 | 616 | 9 | 29,5 |
**The number of installed elements depends on their dimensions and contact group sizes. The exact number of elements and housing size for a specific solution are specified when placing an order. Modular explosion-proof control panels can be manufactured according to the customer's specifications.
Example: PKIE111109-1KGE07K20-KNV1(G)-TU 27.12.31-037-72453807-2017
- Housing size:PKIE111109
- Mushroom button with locking, released by rotation, 2NO contacts:KGE07K20
- Cable entry size KNV1, location side (G): KNV1(G)
- TU 3400-005-72453807-07
Example: PKIE171109-KGE01CH20- KGE01K20- KGE07K20-KNV1(G)-TU 27.12.31-037-72453807-2017
- Enclosure size:PKIE171109
- Black pushbutton without locking, 2NO contacts: KGE01CH20
- Red pushbutton without locking, 2NO contacts: KGE01K20
- Mushroom pushbutton with locking, released by rotation, 2NO contacts:KGE07K20
- Cable entry size KNV1, location side (G): KNV1(G)
- TU 3400-005-72453807-07
Example: PKIE141410-3KGE01Z11-KGE01K20-KNV1(G)-TU 27.12.31-037-72453807-2017
- Housing size: PKIE141410
- Three "3" green pushbuttons without locking, contacts 1NO+1NC: 3KGE01Z11
- Red pushbutton without locking, contacts 2NO: KGE01K20
- Cable entry size KNV1, location side (G): KNV1(G)
- TU 3400-005-72453807-07
Example: PKIE301410-KGE01Z20-LGE03Z220-LGE03K220-KGE08K11-KGE01K20-KGE01CH02-PGE1S-PGE2S-KNVM2M-20(G)-TU 27.12.31-037-72453807-2017
- Body size: PKIE301410
- Green pushbutton without locking, 2NO contacts: KGE01Z20
- Green luminaire, ~220-380 V: LGE03Z220
- Red luminaire, ~220-380 V: LGE03K220
- "Mushroom" pushbutton with locking, released by rotation, 1NO+1NC contacts: KGE08K11
- Red pushbutton without locking, contacts 2NO: KGE01K20
- Black pushbutton without locking, contacts 2N3: KGE01CH02
- 3-position switch with zero circuit 1C: PGE1S
- 3-position switch with zero circuit 2C: PGE2S
- Cable entry KNVM2M-20, for connection of unarmored cable in metal sleeves, location side "G": KNVM2M-20(G)
- TU 3400-005-72453807-07
Drag files here
CAD " GORELTEX ", questionnaires, necessary documents

If the "enclosure size" is not specified, a case will be selected that is optimally suited to the layout of the specified set of components. The number of components is specified when installing multiple identical units.
Head office and production site
Sales office
Sales office
Sales office and production site
Sales office
Sales office