Explosion-proof distribution and pull-through boxes of the SKV series

Product Description

SKV are explosion-proof boxes with 1–4 entry ports, designed for pulling and branching cables and wires in conduit wiring systems in hazardous areas. The housing is made of corrosion-resistant aluminum alloy with alloying modifiers, allowing the boxes to be used in aggressive environments, including marine environments.

Advantages

  • Can be mounted on both walls and ceilings, which is especially important when installing in confined spaces or complex load-bearing structures
  • Certified equipment ensuring safety and uninterrupted operation.
  • The aluminum housing shell combines exceptional mechanical strength, corrosion resistance and efficient heat dissipation

Frequently bought together

Compliance with standards

GOST 14254-96 (IEC 529-89)
GOST R IEC 60079-0-2011
GOST 30852.0-2002 (IEC 60079-0:1998)
GOST 30852.1-2002 (IEC 60079-1:1998)
GOST R IEC 60079-31-2010
GOST 30852.8-2002 (IEC 60079-0:1998)
GOST 22782.3-77
GOST 30852.10-2002 (IEC 60079-11:1999)
GOST IEC 61241-1-1-2011
GOST 24754-2013
TR CU 012/2011
TR CU 004/2011
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
GOST 30852.20-2002

Certificates

Markings

Explosion protection marking
1Ex db IIC T6...T4 Gb
1Ex db eb IIC T6...T4 Gb
1Ex ia IIC T6...T4 Gb
1Ex db ib IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db

Housing (EX component)Box (EX component):
Ex db IIC Gb U
Ex ia IIC Gb U
Ex e IIC Gb U
Ex ia IIIС Da U
Ex tb IIIС Db U
Marking of mining equipment
RN1/RN2
Degree of protection
IP66/IP67/IP68
IK10
Installation
Category II for gas subgroups IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust atmospheres containing volatile particles, non-conductive and conductive dust;
Underground workings that are not hazardous for gas (methane) and coal dust;
Non-hazardous zone of surface structures and open areas

Technical data

Ambient temperature, °C
-60...+40 (T6/T85°C)
-60...+60 (T5/T100°C)
-60...+85 (T4/T135°C)
-60…+85 (for PH2 version)
-60...+150 (for Ex-components)
Maximum voltage, V
750
Maximum current, A
175
Thread
Metric GOST 24705-2004 (other threads upon agreement)
Coating
Antistatic polymer-epoxy coating, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Material
Aluminum alloy with alloying modifiers
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

Explosion-proof distribution and junction boxes SKV
Type Number of inlet holes, pcs./Diameter F, mm Drawing Lid diameter, mm H A1 A2 B C X Weight, kg
SKV-O90M1 1 x M20x1.5 Explosion-proof boxes of the SKV-O series 90 75,5 114 122 - 0,6
SKV-O90M2 1 x M25x1.5 0,6
SKV-O90M3 1 x M32x1.5 0,6
SKV-O144M1 1 x M20x1.5 144 115 175 - - 2,5
SKV-O144M2 1 x M25x1.5 2,4
SKV-O144M3 1 x M32x1.5 2,3
SKV-O144M4 1 x M40x1.5 2,2
SKV-O144M5 1 x M50x1.5 2,1
SKV-O144M6 1 x M63x1.5 2
SKV-P90M1 2 x M20x1.5 SKV-P 90 75,5 106 122 - 0,5
SKV-P90M2 2 x M25x1.5 0,5
SKV-P90M3 2 x M32x1.5 0,5
SKV-P144M1 2 x M20x1.5 144 119 175 - - 2,4
SKV-P144M2 2 x M25x1.5 2,3
SKV-P144M3 2 x M32x1.5 2,2
SKV-P144M4 2 x M40x1.5 2,1
SKV-P144M5 2 x M50x1.5 2
SKV-P144M6 2 x M63x1.5 1,9
SKV-U90M1 2 x M20x1.5 SKV-U 90 75,5 114 114 - 0,5
SKV-U90M2 2 x M25x1.5 0,5
SKV-U90M3 2 x M32x1.5 0,5
SKV-U144M1 2 x M20x1.5 144 115 175 - - 2,4
SKV-U144M2 2 x M25x1.5 2,3
SKV-U144M3 2 x M32x1.5 2,2
SKV-U144M4 2 x M40x1.5 2,1
SKV-U144M5 2 x M50x1.5 2
SKV-U144M6 2 x M63x1.5 1,9
SKV-T90M1 3 x M20x1.5 SKV-T 90 75,5 106 114 - 0,5
SKV-T90M2 3 x M25x1.5 0,5
SKV-T90M3 3 x M32x1.5 0,5
SKV-T144M1 3 x M20x1.5 144 115 175 - - 2,3
SKV-T144M2 3 x M25x1.5 2,2
SKV-T144M3 3 x M32x1.5 2,1
SKV-T144M4 3 x M40x1.5 2
SKV-T144M5 3 x M50x1.5 1,9
SKV-T144M6 3 x M63x1.5 1,8
SKV-K90M1 4 x M20x1.5 SKV-K 90 75,5 106 - - 0,6
SKV-K90M2 4 x M25x1.5 0,6
SKV-K90M3 4 x M32x1.5 0,5
SKV-K144M1 4 x M20x1.5 144 115 175 - - 2,3
SKV-K144M2 4 x M25x1.5 2,2
SKV-K144M3 4 x M32x1.5 2,1
SKV-K144M4 4 x M40x1.5 2
SKV-K144M5 4 x M50x1.5 1,9
SKV-K144M6 4 x M63x1.5 1,7
SKV-OS90M1 1 x M20x1.5 SKV-OS 90 75,5 114 122 130 - 109 0,6
SKV-OS90M2 1 x M25x1.5 0,6
SKV-OS90M3 1 x M32x1.5 0,6
SKV-OC144M1 1 x M20x1.5 144 119 175 - 190 - 170 2,7
SKV-OC144M2 1 x M25x1.5 2,6
SKV-OC144M3 1 x M32x1.5 2,5
SKV-OC144M4 1 x M40x1.5 2,4
SKV-OC144M5 1 x M50x1.5 2,3
SKV-OC144M6 1 x M63x1.5 2,2
SKV-PS90M1 2 x M20x1.5 SKV-PS 90 75,5 106 122 130 - 109 0,6
SKV-PS90M2 2 x M25x1.5 0,6
SKV-PS90M3 2 x M32x1.5 0,6
SKV-PS144M1 2 x M20x1.5 144 119 175 - 190 - 170 2,6
SKV-PS144M2 2 x M25x1.5 2,5
SKV-PS144M3 2 x M32x1.5 2,4
SKV-PS144M4 2 x M40x1.5 2,3
SKV-PS144M5 2 x M50x1.5 2,2
SKV-PS144M6 2 x M63x1.5 2,2
SKV-US90M1 2 x M20x1.5 SKV-US 90 75,5 114 114 130 - 109 0,6
SKV-US90M2 2 x M25x1.5 0,6
SKV-US90M3 2 x M32x1.5 0,6
SKV-US144M1 2 x M20x1.5 144 119 175 - 190 - 170 2,6
SKV-US144M2 2 x M25x1.5 2,5
SKV-US144M3 2 x M32x1.5 2,4
SKV-US144M4 2 x M40x1.5 2,3
SKV-US144M5 2 x M50x1.5 2,2
SKV-US144M6 2 x M63x1.5 2,1
SKV-TS90M1 3 x M20x1.5 SKV-TS 90 75,5 106 114 130 - 109 0,6
SKV-TS90M2 3 x M25x1.5 0,6
SKV-TS90M3 3 x M32x1.5 0,6
SKV-TC144M1 3 x M20x1.5 144 119 175 - 190 - 170 2,5
SKV-TC144M2 3 x M25x1.5 2,4
SKV-TC144M3 3 x M32x1.5 2,3
SKV-TC144M4 3 x M40x1.5 2,2
SKV-TC144M5 3 x M50x1.5 2,1
SKV-TC144M6 3 x M63x1.5 2
SKV-KS90M1 4 x M20x1.5 SKV-KS 90 75,5 106 106 130 - 109 0,7
SKV-KS90M2 4 x M25x1.5 0,7
SKV-KS90M3 4 x M32x1.5 0,6
SKV-KS144M1 4 x M20x1.5 144 119 175 - 190 - 170 2,5
SKV-KS144M2 4 x M25x1.5 2,4
SKV-KS144M3 4 x M32x1.5 2,3
SKV-KS144M4 4 x M40x1.5 2,2
SKV-KS144M5 4 x M50x1.5 2,1
SKV-KS144M6 4 x M63x1.5 1,9
SKV-TSG90M1 3 x M20x1.5 SKV-TSG 90 75,5 106 - 125 121 111 0,7
SKV-TSG90M2 3 x M25x1.5 0,7
SKV-TSG90M3 3 x M32x1.5 0,6
SKV-TSG144M1 3 x M20x1.5 144 120 175 - 160 186 130 3,4
SKV-TSG144M2 3 x M25x1.5 3,3
SKV-TSG144M3 3 x M32x1.5 3,2
SKV-TSG144M4 3 x M40x1.5 3,1
SKV-TSG144M5 3 x M50x1.5 3
SKV-TSG144M6 3 x M63x1.5 2,9

Options

Options, accessories and versions
Marking
Painting the outer surface in the color according to the customer's requirements
/RAL (code)
Anti-condensation coating
/AP
Non-explosion-proof design
/PROM
Mining normal design
/RN
Stainless steel lid chain
/CHAIN

3D models

STP models
zip
Download

Additional information

Main characteristics of the installed terminal cluminaires
TERMINAL TYPE NOMINAL CROSS-SECTION, MM2 RATED CURRENT, A MAXIMUM VOLTAGE, V OVERALL DIMENSIONS, MM
A IN WITH
WDU2.5 2,5 24 800 5 60 47
WDU4 6 32 800 6 60 47
WDU6 10 41 800 8 60 47
WDU10 16 57 800 10 60 47
WDU16 25 76 10000 12 60 63
WDU35 50 125 10000 16 60 63

The maximum permissible number of installed small-sized terminals AKZ
Nominal cross-section of wire, mm2 Number of terminals
1,5 2,5 4
SKV-K90 6 5 5
SKV-K144 15 14 12

Maximum allowed number of installed WDU terminals
Nominal cross-section of wire, mm2 Number of terminals
2,5 4 6 10 16 35
SKV-K144 14 12 9 7 5 -
*This number of terminal blocks is indicated without taking into account the installation of cable glands

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Model Breakdown
SKV - 1X 2X 3X / 4X – TU 27.33.13-033-72453807-2017
1X - Hole Location
2X - Size code
3X - Thread code and size
4X - Options, accessories and versions

Please note:

  1. To determine the thread equivalent, see the table of thread types produced by ZAVOD GORELTEX CO. LTD.
  2. To order distribution boxes with terminal blocks, you must specify in the order form the quantity and type of terminal blocks, as well as the quantity, type and side of the cable glands.
  3. The default thread in the box holes is metric GOST 24705-2004.
  4. To find out the maximum number of terminal blocks of different cross-sections that can be installed in boxes, see the table "Maximum number of installed terminal cluminaires"
  5. For the type and order code of the terminal cluminaires, see the table "Main characteristics of the installed terminal cluminaires"

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Read more
193149, Russia, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1

Moscow

Sales office

Read more
123112, Russia, Moscow, Presnenskaya embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15

Kazan

Sales office

Read more
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110