Saint Petersburg
Head office and production site
1Ex 60079-30-1 IIC T3 Gb X*
Ex 60079-30-1 IIIC T200°C Db X*
1Ex 60079-30-1 IIC T2 Gb X*
Ex 60079-30-1 IIIC T260°C Db X*| Name | Cross-section of the core, mm2 | Maximum screen resistance, Ohm/km | Nominal cable size, mm | Minimum bending radius of cable at -20°C, mm | Nominal weight, kg/km | Conductor resistance, Ohm/km |
|---|---|---|---|---|---|---|
| GTG-KR-3-200-035S5 | 0,5 | 7 | (9.90 x 4.90) ± 0.20 | 30 | 116,35 | 35,5 |
| GTG-KR-3-200-023S3 | 0,75 | (10.53 x 5.11) ± 0.20 | 130,24 | 23,3 | ||
| GTG-KR-3-200-018S1 | 1 | (10.98 x 4.90) ± 0.20 | 141,08 | 18,1 | ||
| GTG-KR-3-200-011S5 | 1,5 | (12.00 x 5.60) ± 0.20 | 167,51 | 11,5 | ||
| GTG-KR-3-200-008S6 | 2 | (12.75 x 5.85) ± 0.20 | 35 | 192,34 | 8,6 | |
| GTG-KR-3-200-005S8 | 3 | (13.95 x 6.25) ± 0.20 | 40 | 235,79 | 5,8 | |
| GTG-KR-3-200-004S3 | 4 | 4 | (15.00 x 6.60) ± 0.20 | 298,75 | 4,3 | |
| GTG-KR-3-200-00003 | 6 | (16.65 x 7.15) ± 0.20 | 45 | 369,04 | 3 | |
| GTG-KR-3-200-002S2 | 8 | 3 | (18.12 x 7.64) ± 0.20 | 55 | 456,76 | 2,2 |
| GTG-KR-3-200-001S7 | 10 | 2,5 | (21.24 x 8.68) ± 0.20 | 60 | 583,2 | 1,7 |
| Name | Cross-section of the core, mm2 | Maximum screen resistance, Ohm/km | Nominal cable size, mm | Minimum bending radius of cable at -20°C, mm | Nominal weight, kg/km | Conductor resistance, Ohm/km |
|---|---|---|---|---|---|---|
| GTG-KR-3-260-035S5 | 0,5 | 7 | (9.90 x 4.90) ± 0.20 | 30 | 116,35 | 35,5 |
| GTG-KR-3-260-023S3 | 0,75 | (10.53 x 5.11) ± 0.20 | 130,24 | 23,3 | ||
| GTG-KR-3-260-018S1 | 1 | (10.98 x 4.90) ± 0.20 | 141,08 | 18,1 | ||
| GTG-KR-3-260-011S5 | 1,5 | (12.00 x 5.60) ± 0.20 | 167,51 | 11,5 | ||
| GTG-KR-3-260-008S6 | 2 | (12.75 x 5.85) ± 0.20 | 35 | 192,34 | 8,6 | |
| GTG-KR-3-260-005S8 | 3 | (13.95 x 6.25) ± 0.20 | 40 | 235,79 | 5,8 | |
| GTG-KR-3-260-004S3 | 4 | 4 | (15.00 x 6.60) ± 0.20 | 40 | 298,75 | 4,3 |
| GTG-KR-3-260-00003 | 6 | 4 | (16.65 x 7.15) ± 0.20 | 45 | 369,04 | 3 |
| GTG-KR-3-260-002S2 | 8 | 3 | (18.12 x 7.64) ± 0.20 | 55 | 456,76 | 2,2 |
| GTG-KR-3-260-001S7 | 10 | 2,5 | (21.24 x 8.68) ± 0.20 | 60 | 583,2 | 1,7 |
Changing any key parameters such as supply voltage or cable length will result in the output power differing from the design, which may require recalculation of the entire system and a change in the heating cable type.
Crossing the strands of a constant-wattage heating cable is not permitted. The minimum permissible gap between strands of a constant-wattage heating cable is 20 mm.
Constant Power Cable Construction:
1. Heating core.
2. Insulation of each individual core with fluoropolymer.
3. Braiding of tinned copper wires (GTG-KR-3-200), nickel-plated wires (GTG-KR-3-260).
4. Fluoropolymer sheath (red for cable GTG-KR-3-200, gray for cable GTG-KR-3-260).
(The design is shown for the GTG-KR-3-200 cable; for the GTG-KR-3-260 cable, the design is similar.)
Drag files here
CAD " GORELTEX ", questionnaires, necessary documents
Example: GTG-KR-3-200-035S5-1000-TU 28.21.13-041-72453807-2017.