Saint Petersburg
Head office and production site
TU 27.12.31-037-72453807-2017
1Ex db [ia Ga] IIC Т6...Т5 Gb
Ex tb [ia Da] IIIC T85˚C...Т100°С DbTemperature sensor is not included in the delivery package.
| Parameter name | SHGVA-PT-401 |
| Sensor type | Pt100 (α = 0.00391 °C-1) 100P (α = 0.00385 °C-1) |
| Internal conductor connection diagram | 4-wire |
| Admission class | A, B (standard), C |
| Ex-marking | 0Ex ia IIC T5 Ga 1Ex ia IIC T5 Gb |
| Providing IPXX protection level | IP66 |
| Parameters of intrinsically safe circuits Um = 250 V | Ui ≥ Uo = 3.47 V; Ii ≥ Io = 100 mA; Pi ≥ Po = 87 mW; Ci ≤ Co = 100 μF; Li ≤ Lo = 8 mH; |

* the diameter of the holes for cable glands is agreed with the customer.
Drag files here
CAD " GORELTEX ", questionnaires, necessary documents

Example: SHGVA-PT-401–1KNV2MN(A)-2KNV1MN(B)–TU 27.12.31-037-72453807-2017
Head office and production site
Sales office
Sales office
Sales office and production site
Sales office
Sales office