Saint Petersburg
Head office and production site
1Ex 60079-30-1 IIC T3 Gb X*
Ex 60079-30-1 IIIC T200°C Db X*
1Ex 60079-30-1 IIC T2 Gb X*
Ex 60079-30-1 IIIC T260°C Db X*| Name | Cross-section of the core, mm2 | Maximum screen resistance, Ohm/km | Nominal cable size, mm | Minimum bending radius of cable at -20°C, mm | Nominal weight, kg/km | Conductor resistance, Ohm/km |
|---|---|---|---|---|---|---|
| GTG-KR-1-200-001S8/GTG-KR-1-260-001S8 | 9,67 | 20 | 8,04 ± 0,2 | 30 | 166,99 | 1,81 |
| GTG-KR-1-200-002S9/GTG-KR-1-260-002S9 | 5,93 | 6,36 ± 0,20 | 113,46 | 2,95 | ||
| GTG-KR-1-200-004S4/GTG-KR-1-260-004S4 | 3,94 | 5,69 ± 0,20 | 87,54 | 4,4 | ||
| GTG-KR-1-200-007S1/GTG-KR-1-260-007S1 | 2,45 | 5,10 ± 0,20 | 66,51 | 7,13 | ||
| GTG-KR-1-200-009S7/GTG-KR-1-260-009S7 | 1,84 | 4,85 ± 0,20 | 57,78 | 9,65 | ||
| GTG-KR-1-200-011S9/GTG-KR-1-260-011S9 | 1,49 | 4,59 ± 0,20 | 52,4 | 11,9 | ||
| GTG-KR-1-200-017S4/GTG-KR-1-260-017S4 | 1,02 | 4,34 ± 0,20 | 45,64 | 17,4 | ||
| GTG-KR-1-200-024S8/GTG-KR-1-260-024S8 | 0,71 | 4,20 ± 0,20 | 41,59 | 24,8 | ||
| GTG-KR-1-200-032S7/GTG-KR-1-260-032S7 | 0,53 | 3,97 ± 0,20 | 37,84 | 32,7 | ||
| GTG-KR-1-200-00050/GTG-KR-1-260-00050 | 0,34 | 3,81 ± 0,20 | 34,69 | 50 | ||
| GTG-KR-1-200-00062/GTG-KR-1-260-00062 | 0,28 | 3,74 ± 0,20 | 33,39 | 62 | ||
| GTG-KR-1-200-00080/GTG-KR-1-260-00080 | 0,22 | 3,60 ± 0,20 | 31,49 | 80 | ||
| GTG-KR-1-200-00100/GTG-KR-1-260-00100 | 0,49 | 3,88 ± 0,20 | 36,41 | 100 | ||
| GTG-KR-1-200-00142/GTG-KR-1-260-00142 | 0,35 | 4,58 ± 0,20 | 51,64 | 142 | ||
| GTG-KR-1-200-00178/GTG-KR-1-260-00178 | 0,28 | 3,97 ± 0,20 | 38,12 | 178 | ||
| GTG-KR-1-200-00200/GTG-KR-1-260-00200 | 0,34 | 4,35 ± 0,20 | 45,67 | 200 | ||
| GTG-KR-1-200-00250/GTG-KR-1-260-00250 | 0,29 | 3,87 ± 0,20 | 35,73 | 250 | ||
| GTG-KR-1-200-00340/GTG-KR-1-260-00340 | 0,21 | 3,98 ± 0,20 | 38,31 | 340 | ||
| GTG-KR-1-200-00410/GTG-KR-1-260-00410 | 0,13 | 3,98 ± 0,20 | 37,57 | 410 | ||
| GTG-KR-1-200-00490/GTG-KR-1-260-00490 | 0,67 | 3,88 ± 0,20 | 35,89 | 490 | ||
| GTG-KR-1-200-00590/GTG-KR-1-260-00590 | 0,34 | 3,78 ± 0,20 | 34,25 | 590 | ||
| GTG-KR-1-200-00665/GTG-KR-1-260-00665 | 0,49 | 4,41 ± 0,20 | 45,73 | 665 | ||
| GTG-KR-1-200-00765/GTG-KR-1-260-00765 | 0,28 | 4,32 ± 0,20 | 43,73 | 765 | ||
| GTG-KR-1-200-01000/GTG-KR-1-260-01000 | 0,2 | 4,50 ± 0,20 | 48,12 | 1000 | ||
| GTG-KR-1-200-01300/GTG-KR-1-260-01300 | 0,15 | 3,97 ± 0,20 | 37,3 | 1300 | ||
| GTG-KR-1-200-01480/GTG-KR-1-260-01480 | 0,3 | 3,90 ± 0,20 | 36,3 | 1480 | ||
| GTG-KR-1-200-01865/GTG-KR-1-260-01865 | 0,56 | 3,83 ± 0,20 | 34,71 | 1865 | ||
| GTG-KR-1-200-02825/GTG-KR-1-260-02825 | 0,49 | 3,86 ± 0,20 | 35,2 | 2825 | ||
| GTG-KR-1-200-03950/GTG-KR-1-260-03950 | 0,35 | 3,81 ± 0,20 | 34,07 | 3950 | ||
| GTG-KR-1-200-05900/GTG-KR-1-260-05900 | 0,18 | 3,58 ± 0,20 | 30,91 | 5900 | ||
| GTG-KR-1-200-07000/GTG-KR-1-260-07000 | 0,2 | 3,56 ± 0,20 | 30,46 | 7000 | ||
| GTG-KR-1-200-08000/GTG-KR-1-260-08000 | 0,13 | 3,52 ± 0,20 | 29,96 | 8000 |
Changing any key parameters such as supply voltage or cable length will result in the output power differing from the design, which may require recalculation of the entire system and a change in the heating cable type.
Crossing the strands of a constant-wattage heating cable is not permitted. The minimum permissible gap between strands of a constant-wattage heating cable is 20 mm.
Constant Power Cable Construction:
1. Heating core.
2. Fluoropolymer insulation.
3. Braid made of nickel-plated copper wires.
4. Fluoropolymer shell.
Drag files here
CAD " GORELTEX ", questionnaires, necessary documents
Example: GTG-KR-1-260-001S8-230 - TU 28.21.13-041-72453807-2017