Saint Petersburg
Head office and production site
1Ex 60079-30-1 IIC T3 Gb X*
Ex 60079-30-1 IIIC T200°C Db X*
1Ex 60079-30-1 IIC T1 Gb X*
Ex 60079-30-1 IIIC T400°C Db X*
1Ex 60079-30-1 IIC T1 Gb X*
Ex 60079-30-1 IIIC T450°C Db X*| Name | Cross-section of the core, mm2 | Nominal cable size, mm | Minimum bending radius of cable at -20°C, mm | Conductor resistance, Ohm/km |
|---|---|---|---|---|
| GTG-KR-1M-200-04S61 | 4,000 | 4,4 | 25 | 4,61 |
| GTG-KR-1M-200-00004 | 4,300 | 5,9 | 4 | |
| GTG-KR-1M-200-07S41 | 2,500 | 3,8 | 7,41 | |
| GTG-KR-1M-200-00007 | 2,500 | 5,3 | 7 | |
| GTG-KR-1M-200-00012 | 1,500 | 3,4 | 12 | |
| GTG-KR-1M-200-00011 | 1,560 | 4,9 | 11 | |
| GTG-KR-1M-200-00018 | 1,000 | 3,1 | 18 | |
| GTG-KR-1M-200-00017 | 1,020 | 4,6 | 17 | |
| GTG-KR-1M-200-00025 | 0,693 | 3,7 | 25 | |
| GTG-KR-1M-200-00040 | 0,429 | 3,4 | 40 | |
| GTG-KR-1M-200-00063 | 0,273 | 3,2 | 63 |
| Name | Cross-section of the core, mm2 | Nominal cable size, mm | Minimum bending radius of cable at -20°C, mm | Conductor resistance, Ohm/km |
|---|---|---|---|---|
| GTG-KR-1M-400-00011 | 1,560 | 4,9 | 7.5 cable diameters | 11 |
| GTG-KR-1M-400-00017 | 1,020 | 4,6 | 17 | |
| GTG-KR-1M-400-00025 | 0,693 | 3,7 | 25 | |
| GTG-KR-1M-400-00040 | 0,429 | 3,4 | 40 | |
| GTG-KR-1M-400-00063 | 0,273 | 3,2 | 63 | |
| GTG-KR-1M-400-00160 | 3,046 | 4,9 | 160 | |
| GTG-KR-1M-400-00250 | 1,960 | 4,4 | 250 | |
| GTG-KR-1M-400-00400 | 1,226 | 4 | 400 | |
| GTG-KR-1M-400-00630 | 0,769 | 3,7 | 630 | |
| GTG-KR-1M-400-01000 | 0,490 | 3,4 | 1000 | |
| GTG-KR-1M-400-01600 | 0,302 | 3,2 | 1600 |
| Name | Cross-section of the core, mm2 | Nominal cable size, mm | Minimum bending radius of cable at -20°C, mm | Conductor resistance, Ohm/km |
|---|---|---|---|---|
| GTG-KR-1M-450-00160 | 6,747 | 6,5 | 7.5 cable diameters | 160 |
| GTG-KR-1M-450-00250 | 4,318 | 5,3 | 250 | |
| GTG-KR-1M-450-00400 | 2,699 | 4,7 | 400 | |
| GTG-KR-1M-450-00630 | 1,713 | 4,3 | 630 | |
| GTG-KR-1M-450-01000 | 1,080 | 3,9 | 1000 | |
| GTG-KR-1M-450-01600 | 0,675 | 3,6 | 1600 | |
| GTG-KR-1M-450-02500 | 0,432 | 3,4 | 2500 | |
| GTG-KR-1M-450-04000 | 0,270 | 3,2 | 4000 | |
| GTG-KR-1M-450-06300 | 0,171 | 3,2 | 6300 | |
| GTG-KR-1M-450-10000 | 0,108 | 3,2 | 10000 |
Changing any key parameters such as supply voltage or cable length will result in the output power differing from the design, which may require recalculation of the entire system and a change in the heating cable type.
Crossing heating cable strands with constant power is not permitted. The minimum permissible gap between heating cable strands is 20 mm.
Constant Power Cable Construction:
1. Heating core.
2. Mineral insulation.
3. Shell made of copper (GTG-KR-1M-200), copper-nickel alloy (GTG-KR-1M-400), stainless steel (GTG-KR-1M-450).
Drag files here
CAD " GORELTEX ", questionnaires, necessary documents
Example: GTG-KR-1M-400-00011-230 - TU 28.21.13-041-72453807-2017.
Head office and production site
Sales office
Sales office
Sales office and production site
Sales office
Sales office