DVG-SHAG Series Explosion-Proof Microwave Motion Sensors

Product Description

The DVG-SHAG explosion-proof motion sensor is designed to automatically turn loads on and off within a specified time interval when moving objects, including mechanical ones, appear within the sensor's detection zone, depending on the light level. It operates using 5.8 GHz microwave radar, receiving echoes reflected from objects.

Advantages

  • Certified equipment ensuring safety and uninterrupted operation.
  • The aluminum alloy body with alloying modifiers combines exceptional mechanical strength and corrosion resistance. The window is impact-resistant tempered glass.
  • Response speed 0.6-1.5 seconds.
  • Adjustable response range 1-4 meters.
  • Protection against mechanical damage IK08 and a high degree of protection against moisture and dust IP66/IP67/IP68/IP69.

Frequently bought together

Compliance with standards

GOST 14254-96 (IEC 529-89)
GOST R IEC 60079-0-2011
GOST 30852.0-2002 (IEC 60079-0:1998)
GOST 30852.1-2002 (IEC 60079-1:1998)
GOST IEC 61241-1-1-2011
Chapter 7.3 of the Electrical Installation Code
GOST 24754-2013
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
TR CU 012/2011
GOST 12.2.007.0-75. Occupational Safety Standards
RD 5.2-093-2004
GOST R IEC 60079-31-2010

Certificates

Markings

Explosion protection marking
1Ex db [ia Ga] IIC Т6...Т5 Gb
Ex tb [ia Da] IIIC T85˚C...Т100°С Db
Marking of mining equipment
RN1/RN2
Degree of protection
IP66/IP67
IK08
Installation
Category II for gas subgroups IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust atmospheres, volatile particles, non-conductive and conductive dust;
Underground workings that are not hazardous for gas (methane) and coal dust;

Technical data

Ambient temperature, °C
-60...+40 (T6/T85°C)
-60...+60 (T5/T100°C)
-60...+60 (PH1/PH2 and general industrial design)
Supply voltage, V
~220-240 (50/60 Hz)
Power consumption, W
0,9
Nominal load, W
1200
Transmission power, mW
< 10 (one hundredth of the mobile phone transmission power)
Threads on connecting holes
Metric GOST 24705-2004
Coating
Antistatic polymer-epoxy coating, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Enclosure material
Aluminum alloy with alloying modifiers. Window - impact-resistant, tempered glass.
Response speed, s
0,6 - 1,5
Illumination level, Lux
3 - 2000 (adjustable)
Switch-off delay, sec
10 - 720 (adjustable)
Response range, m
1 - 4 (adjustable)
High frequency system, GHz
5,8
Installation height, m
1,5 - 3,6
Weight, kg
4
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

DVG-SHAG Series Explosion-Proof Microwave Motion Sensors

Options

Options, accessories and versions
Marking
Painting the outer surface in the color according to the customer's requirements
/RAL (code)
Marine version
/MORE
Non-explosion-proof design
/PROM
River execution
/RIVER
Mining normal design
/RN
Mounting bracket
/BRACKET
Option Correspondence Table
PROM SEA RIVER RN BRACKET RAL (code)
PROM + + + + +
SEA + + - + +
RIVER + + - + +
RN + - - + +
BRACKET + + + + +
RAL (code) + + + + +

Additional information

CONNECTION DIAGRAM
Connection diagram

SETUP

The dimmer allows you to adjust the light level at which the motion sensor turns off the load. The minimum light level at which the load is not activated is 2 lux. The maximum light level at which the load is activated is 2000 lux.

The delay regulator allows you to adjust the load time connected to the sensor. The maximum operating time is 12 minutes. If the sensor is triggered during the timer period, the countdown restarts.

The range controller adjusts the sensor's detection distance of a moving object. When the sensor is installed at a height of 2.5 meters, the minimum range controller position corresponds to 1 meter, and the maximum range controller position corresponds to 4 meters.

Submit request

Configurator
Number and size of cable glands
Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Model Breakdown
DVG-STEP - 1X / 2X – TU 27.12.31-037-72453807-2017
1X - Number and size of cable glands
2X - Options, accessories and versions

Example: DVG-STEP-KNV2N/AP-TU 27.12.31-037-72453807-2017.

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more