• Distribution and Terminal Boxes
  • Control and Automation Cabinets
  • Lighting Equipment
  • Control and Indicating Stations
  • Visual, Audible and Signaling Devices
  • Electrical Heating and Fans
  • Video Surveillance
  • IT equipment
  • Spark protection barriers and functional safety relays
  • Cable Glands, Conduits
  • Sockets, Plugs, Extension cords
  • Switches, Selectors Switches, Sensors
  • Control and Measuring Instruments
  • Cable/Pipe Transits
  • Electrical Components and Materials
Logo

SHGV-UZG Explosion-Proof Grounding Monitoring Device

Product Description

SHGV-UZG series explosion-proof grounding monitoring device, based on an enclosure made of corrosion-resistant aluminum alloy with alloying modifiers, provides monitoring of the electrostatic grounding of road and rail tankers, and reservoirs during the loading of flammable liquids, explosive bulk materials, and gases.

Advantages

  • Certified equipment ensuring safety and uninterrupted operation.
  • Continuous monitoring system for grounding conditions.
  • High-precision digital circuit for measuring contact resistance, eliminating interference.
  • Automatic blocking of filling/draining actuators in case of grounding circuit failure.
  • High response speed - no more than 10 ms.
  • The device controls a resistance of 10 Ohms to prevent the occurrence of static electricity in explosive environments (compliance with GOST requirements).
  • 3 pliers contact points for secure electrical connection and fixation.
  • Availability of a display panel indicating the status of the resistance circuit.
  • The length of the cluminaire cable can be up to 50 m, as per customer requirements.

Frequently bought together

Compliance with standards

GOST R IEC 60079-0-2011
GOST 14254-96 (IEC 529-89)
GOST 30852.10-2002 (IEC 60079-11:1999)
GOST IEC 60079-1-2011
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
TR CU 012/2011

Certificates

Markings

Explosion protection marking
1Ex db ia IIC T6 Gb X
1Ex db ia IIB+H2 T6 Gb
Ex ia tb IIIC T85°C Db

For versions with current switched by the power output higher than 2A:
1Ex db ia IIC T5 Gb X
1Ex db ia IIB+H2 T5 Gb
Ex ia tb IIIC T95°C Db
Degree of protection
IP66
Installation
Category II for gas subgroup IIA, IIB+H2,IIC (except acetylene), zones 1, 2

Technical data

Ambient temperature, °C
-60...+60 (T6/85°С)
Supply voltage, V
~230±10% (50Hz)
Maximum voltage switched by the power output (effective value), V
220 (DC)
250 (AC)
Number of power outputs
2
Power consumption, VA
no more than 10
Maximum power of the electric motor switched by the power output
62.5 VA
60 W
The time between the moment the ground cluminaires are disconnected from the grounded equipment and the appearance of a signal at the outputs, ms
no more than 10
Threshold value of input resistance, Ohm
no more than 10
Number of grounding channels (inputs for connecting grounding cluminaires), pcs
1
Transient resistance measurement circuit
Digital
Coating
Antistatic polymer-epoxy coating, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Enclosure material
Aluminum alloy with alloying modifiers
Power output type
Electromagnetic relay contact
Protection class against electric shock
I
Weight, kg
7
Climatic category
for groups II, III: U1…5, HL1…5, NF1…5, TV1…4, T W5 , T1…2, TS1…2, T2.1, T3, TS3…4, O1…5, B1…5.

Design parameters

Explosion-proof grounding devices SHGV-UZG

The number and size of cable glands are determined according to the customer’s needs.

Options

Options, accessories and versions
Marking
Painting the outer surface in the color according to the customer's requirements
/RAL (code)
Aluminum alloy mounting panel
/ALP
Anti-condensation coating
/AP
Earthquake-resistant design
/MSHK-64
A plate with the customer's inscription
/NADPIS "_"
Captive cover mounting bolts
/NBK
Stainless steel mounting plate
/NP
Bolt with seal
/SEAL
Non-explosion-proof design
/PROM
Tropical version with insect protection
/TERMITY

Additional information

CONNECTION AND OPERATION:

Contrast perception of information on a light board from a distance under any lighting conditions

The cluminaire (pliers) is attached to the metal part of the tank truck body. After pressing the "MEASUREMENT" button, static electricity flows from the tank truck (AT) through one of the grounding conductor wires to the grounding main (PE). The second wire measures the grounding circuit resistance, the transition resistance between the cluminaire contacts, and the resistance of the grounding conductor wires. If the total measured resistance does not exceed (8 ± 2) ohms, the "GROUNDED" indicator panel lights, authorizing the tank truck loading/unloading operation.

To measure the contact resistance, the following sequence of actions must be followed:

1. Connect the grounding conductor cluminaires to an unpainted metal part of the tank truck.

2. Turn the "NETWORK" switch to the "ON" position. Observe the "NOT GROUNDED" indicator (red indicator panel).

3. Hold down the “MEASURE” button for 2 seconds.

4. If the total contact resistance is within (8±2) ohms, the "NOT GROUNDED" indicator light (red indicator panel) will go out and the "GROUNDED" indicator light (orange indicator panel) will light. Five seconds after the "GROUNDED" indicator light turns on, the tanker's filling/unloading operation will begin, and the "PUMP ON" indicator light (green indicator panel) will light.

5. If after 2 seconds there is no change in the status of the light indicator, then move the “NETWORK” switch to the “OFF” position, check the connection of the measuring cluminaires and repeat steps 2-4.


Grounding control during loading and unloading of explosive products and prevention of ignition due to electrostatic discharge.

Careful examination of production and technological processes reveals numerous sources of electrostatic charge that are difficult to detect and easy to miss, and as a result, they become a source of ignition in hazardous areas.

There are many examples of explosions and fires caused by static electricity during loading and unloading operations of liquid and bulk fire and explosion hazardous substances.

Between contacting bodies, especially when they rub, a contact potential difference arises. Its magnitude depends on a number of factors, including the dielectric properties of the materials, the magnitude of their mutual pressure during contact, the humidity and surface temperature of these bodies, and climatic conditions. Upon subsequent separation of these bodies, each retains its electric charge, and as the distance between them increases (as the electrical capacitance of the system decreases), the potential difference increases due to the work performed to separate the charges and can reach tens or hundreds of kilovolts. If the field strength is broken down by physical contact or charge level, a discharge occurs. The discharge energy can exceed the minimum ignition energies of all groups of potentially explosive gas atmospheres.

Object
Energy reserve at 10 kW
Energy reserve at 30 kW
Minimum ignition energy
propanol
methane
hexane
Tanker truck
250 mJ
2,250 mJ
0.65 mJ
0.28 mJ
0.24 mJ

Static discharge in hazardous areas must be avoided at all costs due to the potential risk of fire or explosion. The most important protection is the safe discharge of static charge through potential equalization or grounding. The use of poorly conductive materials in hazardous areas is prohibited.

The transportation, loading, and unloading of chemical and oil and gas products are inherently subject to the constant buildup of electrostatic charge. Any transport operation and movement of raw materials inevitably involves friction, which is the primary cause of electrostatic charge, especially when large quantities of cargo must be moved in a short period of time, such as when loading or unloading large tankers. Stationary tanks present little problem due to the safe discharge of charge through a ground connection. A permanent ground connection is impossible for mobile tanks, such as rail tankers and tank trucks. Therefore, safe grounding must be ensured during loading and unloading operations using special devices.

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Model Breakdown
SHGV-UZG - 1X - 2X / 3X – TU 27.12.31-046-72453807-2017
1X - Length of grounding cable, m: 10, 20, 30 (other upon approval)
2X - Number, size of cable glands
3X - Options, accessories and versions

Example: SHGV-UZG-20-2KOV2/AP-TU 27.12.31-046-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more