KSRV-N Stainless Steel Explosion-Proof Junction Boxes

Product Description

The KSRV-N explosion-proof terminal box with Ex e/Ex i protection type is made of stainless steel. It is used for switching, distributing, and connecting electrical circuits in hazardous areas. The Ex e protection principle prevents sparks and overheating, while the Ex i components installed inside ensure intrinsic safety of the internal circuits. It ensures easy installation and maintenance.

Advantages

  • Certified equipment ensuring safety and uninterrupted operation.
  • The body is made of stainless steel, resistant to aggressive environments, alkalis, sulfuric and hydrochloric acids.
  • Double-sided electrochemical polishing ensures a durable and aesthetic appearance.
  • Certified for food, oil and gas, chemical, marine and mining applications.
  • Terminal boxes KSRV-N are included in the register of Russian industrial products.

Frequently bought together

Compliance with standards

GOST 12.2.007.0-75. Occupational Safety Standards
GOST 14254-96 (IEC 529-89)
GOST 30852.0-2002 (IEC 60079-0:1998)
GOST 30852.8-2002 (IEC 60079-0:1998)
GOST 30852.13-2002 (IEC 60079-14:1996)
GOST 30852.20-2002
TR CU 012/2011
TR CU 004/2011
GOST IEC 61241-1-1-2011
GOST 24754-2013
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
GOST 31610.0-2014 (IEC 60079-0:2011)
GOST IEC 60079-1-2013
GOST 31610.11-2014 (IEC 60079-11:2011)
GOST IEC 60079-31-2013
GOST R IEC 60079-7-2012
GOST 31610.15-2014/IEC 60079-15:2010
GOST R IEC 60079-18-2012
GOST IEC 60079-14-2013 GOST 31610.0-2019 (IEC 60079-0:2017)

Certificates

Markings

Explosion protection marking
KSRV-N when installing terminals:KSRV-N when installing terminals:
0Ex ia IIC T6...T4 Ga X
1Ex eb IIC T6...T4 Gb
1Ex ia IIC T6...T4 Gb
Ex ib IIIC T85°...T135°С Db
Ex tb IIIC T85°...T135°С Db

KSRV-N when installing tires:KSRV-N when installing busbars:
1Ex eb IIC T6...T4 Gb
Ex tb IIIC T85°...T135°С Db

Housing (EX component)Box (EX component):
Ex eb IIC Gb U
Ex tb IIIC Db U
Marking of mining equipment
RP Ex eb I Mc
РВ Ex ib I Mb
PO Ex ia I Ma
RN1, RN2

Housing (EX component)Box (EX component):
Ex eb I Mc U
Degree of protection
IP66/IP67
IK10
Installation
Category I for firedamp and dust;
Category II for gas subgroups IIA, IIB, IIC, zones 0, 1, 2;
Category III for dust, explosive dust atmospheres containing volatile particles,
non-conductive and conductive dust;
Underground workings of mines and shafts hazardous due to gas (methane), coal dust;
Non-hazardous zone of surface structures and open areas;
Facilities supervised by RMRS

Technical data

Ambient temperature, °C
-60...+40 (T6/T85°C)
-60...+60 (T5/T100°C)
-60...+70 (T4/T135°C)
-60...+85 (T4/T135°C)
-60...+85 (for explosion-proof mine equipment and normal mine equipment)

For the "/TERMO" version, °C:
-60...+145 (T3/T200°C)
-60...+185 (T2/T300°C)

For empty enclosures (Ex components), °C:
-60...+150
-60…+290 (for the "/TERMO" version)
Maximum voltage, V
~ 10000 / ~1000 / ⎓600
Maximum current, A
1500 / 800
Placement of cable glands
According to customer specifications.
Grounding
2 ground cluminaires (internal and external) made of stainless steel
Cover fastening
On hinges, fixed with bolts (for KSRV-N111109 and KSRV-N171109 hinges are optional)
Mounting inside the case
4 posts for mounting the mounting panel
Sealing
Silicone rubber (in the lid groove)
Material
Stainless steel grade 08X18N10 according to GOST 5632-2014 (AISI 304), resistant to high temperatures and corrosion.
Working position in space
Any
Protection class against electric shock
I
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

Drawing of explosion-proof boxes of the KSRV-N type made of stainless steel

Overall and connection dimensions of the KSRV-N housings
Box size External dimensions, mm Fastening, mm Weight, kg
Method 1 Method 2
A IN WITH G1 H1 G2 H2
KSRV-N111109 110 110 90 80 137 137 80 1,50
KSRV-N151512 150 150 120 120 177
177
120 2,00
KSRV-N171109 176 116 95 14614320386 1,90
KSRV-N202012 200 200 120 170227227170 2,60
KSRV-N231815 230 180 150 200207257150 3,39
KSRV-N232312 230 230 120 200257257200 3,75
KSRV-N232315 230 230 150 200257257200 4,04
KSRV-N271815 270 180 150 240 204 294 150 3,83
KSRV-N303012 300 300 120 270327327270 4,60
KSRV-N322312 320 230 120 290257347200 4,99
KSRV-N342315 340 230 150 310257367200 5,60
KSRV-N343415 340 340 150 310367367310 7,56
KSRV-N402315 400 230 150 370257427200 6,43
KSRV-N453415 450 340 150 420367477310 9,56
KSRV-N534315 530 430 150 500457557400 13,27
KSRV-N606025 600 600 250 570627627570 22,2
KSRV-N806030 800 600 300 770627827570 29,9
KSRV-N1008030 1000 800 300 9708271027770 44,1

Custom-sized enclosures are available upon customer request, with maximum dimensions of 1000 x 1200 x 400 mm. Locks can be installed on the enclosure lid. Please contact our sales representative for the minimum order quantity for custom-sized enclosures.

Mounting panel
Overall dimensions of mounting panels
Mounting panel
by box type
Dimensions, mm
A B a b
KSRV-N111109 60 60 50 50
KSRV-N151512 100 100 90 90
KSRV-N171109 126 66 116 56
KSRV-N202012 150 150 140 140
KSRV-N231815 180 130 170 120
KSRV-N232312 180 180 170 170
KSRV-N232315 180 180 170 170
KSRV-N271815 220 130 210 120
KSRV-N322312 270 180 160 250
KSRV-N342315 290 180 270 160
KSRV-N343415 290 290 270 270
KSRV-N402315 350 180 330 160
KSRV-N453415 400 290 390 280
KSRV-N534315 480 380 470 370
KSRV-N606025 540 540 530 530
KSRV-N806030 540 740 520 720
KSRV-N1008030 740 940 920 720

Options

Options, accessories and versions
Marking
Stainless steel grade 08x17M13M2T according to GOST 5632-2014 (AISI 316)
/316
Drainage ventilation devices
/DKUE
Lid lock
/ZAMOK
Design for operation at nuclear power plants
/MALAYA TECH
Marking of terminal cluminaires according to the customer's diagram
/MARK
Marine version
/MORE
Earthquake-resistant design
/MSHK-64
A plate with the customer's inscription
/NADPIS "_"
Stainless steel mounting plate
/NP
Viewing window according to customer's size
/O(SIZE)
Thermal heating for automation
/OBOGREV
Fixing the lid on hinges
/LOOP
Bolt with seal
/SEAL
Compliance with fire safety requirements
/POZHAR
Customer acceptance
/PRIEMKA
Non-explosion-proof design
/PROM
River execution
/RIVER
Mining normal design
/RN
Replacement plates for cable glands
/SPKV
The presence of jumpers between terminal cluminaires according to the customer's diagram
/SCHEME
Internal thermal insulation
/TEPLOISOLATSIA
Tropical version with insect protection
/TERMITY
High temperature version
/TERMO
Internal grounding busbar
/TIRE Z
Neutral busbar
/TIRE N
Device for combining cable screens
/SCREEN

Note: For the /BUS Z and /BUS H , the default installation is with buses having 2 x 16 mm2 holesand a row of 6 mm2 holes( the number depends on the bus length). Busbars with a different hole diameter can be installed upon agreement with the customer.

3D models

STP models
zip
Download
Revit models
zip
Download

Additional information

All KSRV-N explosion-proof enclosure covers, except for the KSRV-N111109 and KSRV-N171109, are supplied with hinges by default. Using hinged covers improves ease of installation, cable and wire connections, and subsequent maintenance.

Maximum number of controls and indicators on the housing cover*
Box size Components with type of protection "Ex de IIC U"
KSRV-N111109 1
KSRV-N151512 3
KSRV-N171109 3
KSRV-N202012 6
KSRV-N231815 7
KSRV-N232312 10
KSRV-N232315 10
KSRV-N271815 9
KSRV-N322312 12
KSRV-N342315 12
KSRV-N303012 16
KSRV-N343415 18
KSRV-N402315 13
KSRV-N453415 27
KSRV-N534315 39
KSRV-N606025 93
KSRV-N806030 127
KSRV-N1008030 206

*The number of installed elements depends on their dimensions and contact group sizes. The exact number of elements and housing size for a specific solution are specified when ordering.

Recommended maximum number of installed cable glands
Box size Side of
the box
Maximum permissible number of cable (pipe) entries
Cable entry sizes and thread types
01 1 2 3 4 5 6 7
G/M G/M G/M G/M G/M G/M G/M G/M
KSRV-N111109 A 2/2 2/2 2/2 1/1 1/1 - - -
B 2/2 2/2 2/2 1/1 1/1 - - -
KSRV-N151512 A 6 /6 6/6 4/4 2/3 1/1 1/1 1/1 -
B 7/7 6/6 5/5 3 /3 2/2 1/1 1/1 -
KSRV-N171109 A 4/5 4/5 3/3 3/3 2/2 - - -
B 2/2 2/2 2/2 1/1 1/1 - - -
KSRV-N202012 A 8/8 8/8 6/6 5/5 3/3 2/2 2/2 1/1
B 8/8 8/8 6/6 5/5 3/3 2/2 2/2 1/1
KSRV-N231815 A 16 /16 14 /14 10/12 7/7 5/5 3/3 1/1 1/1
B 13/13 12/12 8/8 5/5 4/4 2/2 2/2 1/1
KSRV-N232312 A 12/12 10 /10 6/6 5/5 2/2 1/1 1/1 1/1
B 11/12 10/10 6/6 5/5 2/2 1/1 1/1 1/1
KSRV-N232315 A 17/17 1515 11/12 7/7 5/5 2/2 1/1 1/1
B 1616 1515 10/11 7/7 5/5 2/2 1/1 1/1
KSRV-N271815 A 20/20 1717 13/13 9/9 5/4 4/4 2/2 1/1
B 13/13 12/12 8/8 5/5 4/4 2/2 2/2 1/1
KSRV-N322312 A 19/19 15/15 10/11 77 4/4 2/2 2/2 1/1
B 14/14 12/12 8/8 5/5 3/3 1/1 1/1 1/1
KSRV-N303012 A 14/14 14/14 11/11 8/8 4/4 3/3 3/3 2/2
B 13/13 13/13 11/11 8/8 4/4 3/3 3/3 2/2
KSRV-N342315 A 28 /28 24/24 17/17 11/11 7/7 4/4 3/3 2/2
B 19/19 16/16 12/12 7/7 5/5 2/2 2/2 1/1
KSRV-N343415 A 27/27 24/24 18/18 10/10 7/7 5/5 2/2 1/1
B 27/27 24/24 18/18 10/10 7/7 5/5 2/2 1/1
KSRV-N402315 A 34/34 30/30 21/22 13/13 9/9 5/5 4/4 2/2
B 19/19 16/16 12/12 7/7 5/5 2/2 2/2 1/1
KSRV-N453415 A 38/38 33/33 22/23 14/14 10/10 7/7 4/4 2/2
B 31/31 27/27 19/19 12/12 8/8 5/5 3/3 2/2
KSRV-N534315 A 46/46 41/41 29/30 17/17 12/12 8/7 5/5 3/3
B 39/39 34/34 25/25 15/15 10/10 7/7 4/4 1/1
KSRV-N606025 A 84/84 81/81 60/60 40/40 26/26 21/21 12/12 10/10
B 83/83 82/82 61/61 40/40 26/26 20/20 14/14 10/10
KSRV-N806030 A 135/135 135/135 99/99 69/69 44/44 38/38 27/27 14/14
B 100/100 100/100 73/73 49/49 35/35 24/24 19/19 10/10
KSRV-N1008030 A 170/170 169/169 125/125 86/86 60/60 49/49 33/33 18/18
B 133/133 132/132 98/98 67/67 47/47 33/33 26/26 14/14
Maximum permissible number of installed WDU terminals (excluding installation of cable glands)
Box size Maximum number of terminals (maximum number of terminals in one row)/nominal wire cross-section, mm2
2,5 4 6 10 16 35 50N 70N 120/150 240
KSRV-N111109 4 3 2 2 - - - - - -
KSRV-N151512 16 14 10 8 7 5 - - - -
KSRV-N171109 20 17 13 10 - - - - - -
KSRV-N202012 45(26) 37(22) 17 13 11 8 7 - - -
KSRV-N231815 44(32) 38(27) 28(21) 22(16) 18(13) 10 9 5 - -
KSRV-N232315 62(32) 52(27) 40(21) 30(16) 23(13) 10 9 8 - -
KSRV-N303012 117(46) 99(38) 75(29) 46(23) 38(19) 28(14) 12 11 - -
KSRV-N322312 96(50) 80(42) 60(32) 46(25) 36(21) 20(16) 13 12 - -
KSRV-N342315 104(54) 86(45) 64(34) 50(27) 40(23) 20(17) 15 13 - -
KSRV-N343415 152(54) 128(45) 96(34) 72(27) 46(23) 34(17) 15 13 - -
KSRV-N402315 130(65) 110(55) 80(42) 42(33) 36(28) 27(21) 18 160 4 -
KSRV-N453415 225(75) 189(63) 132(48) 104(39) 64(32) 48(24) 30(20) 26(19) 8 7
KSRV-N534315 364(90) 304(75) 184(58) 148(46) 120(38) 92(29) 54(25) 36(22) 14 12
KSRV-N606025 412(102) 344(85) 264(66) 212(52) 176(43) 132(32) 78(28) 50(25) 16 14
KSRV-N806030 568(102) 476(85) 364(66) 292(52) 244(43) 180(32) 112(28) 72(25) 16 14
KSRV-N1008030 724(180) 604(151) 468(116) 372(93) 308(77) 232(57) 200(49) 140(45) 56(28) 40(25)

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Contact Sales Department Download questionnaire Configure in CAD
Model Breakdown
KSRV-N 1X ( 2X 3X - 2X 3X ) - 4X 5X ( 6X ) - 4X 5X ( 6X ) / 7X – TU 27.33.13-033-72453807-2017
1X - Size Code
2X - Number of terminal cluminaires
3X - Terminal cluminaire type
4X - Number of cable glands
5X - Cable entry type
6X - Input side Sides of cable entry locations
7X - Options, accessories and versions

Example: KSRV-N 271815 (20C2-4C10-1PE10)-2KNV1N(B)-1KOV3N(A)-2KOV3N(V)-TU 27.33.13-033-72453807-2017

If you have difficulty choosing the box size based on the required characteristics, put the letter X instead of numbers after the box name.

Example: KSRV-N X (20C2-4C10-1PE10)-2KNV1N(B)-1KOV3N(A)-2KOV3N(V)-TU 27.33.13-033-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more