• Distribution and Terminal Boxes
  • Control and Automation Cabinets
  • Lighting Equipment
  • Control and Indicating Stations
  • Visual, Audible and Signaling Devices
  • Electrical Heating and Fans
  • Video Surveillance
  • IT equipment
  • Spark protection barriers and functional safety relays
  • Cable Glands, Conduits
  • Sockets, Plugs, Extension cords
  • Switches, Selectors Switches, Sensors
  • Control and Measuring Instruments
  • Cable/Pipe Transits
  • Electrical Components and Materials
Logo

Explosion-proof boxes KSRV-M made of mild steel

Product Description

The KSRV-M explosion-proof terminal box with Ex e/Ex i protection is made of mild steel. It is used for switching, distributing, and connecting electrical circuits in hazardous areas of mines, quarries, and underground workings. The Ex e protection principle prevents sparks and overheating, while the Ex i components installed inside ensure intrinsic safety of internal circuits. It ensures easy installation and maintenance.

Advantages

  • Certified equipment ensuring safety and uninterrupted operation.
  • Corrosion resistance and durability - polymer-epoxy coating protects against aggressive environments.
  • Mild steel body designed to withstand the extreme conditions of underground mines and workings.
  • Terminal boxes KSRV-M are included in the register of Russian industrial products.

Frequently bought together

Compliance with standards

GOST 12.2.007.0-75. Occupational Safety Standards
GOST 14254-96 (IEC 529-89)
GOST 30852.0-2002 (IEC 60079-0:1998)
GOST 30852.8-2002 (IEC 60079-0:1998)
GOST 30852.13-2002 (IEC 60079-14:1996)
GOST 30852.20-2002
TR CU 012/2011
TR CU 004/2011
GOST IEC 61241-1-1-2011
GOST 24754-2013
Chapter 7.3 of the Electrical Installation Code
Chapter 7.4 of the Electrical Installation Code
RD 5.2-093-2004
GOST 31610.0-2014 (IEC 60079-0:2011)
GOST IEC 60079-1-2013
GOST 31610.11-2014 (IEC 60079-11:2011)
GOST IEC 60079-31-2013
GOST R IEC 60079-7-2012
GOST 31610.15-2014/IEC 60079-15:2010
GOST R IEC 60079-18-2012
GOST IEC 60079-14-2013 GOST 31610.0-2019 (IEC 60079-0:2017)

Certificates

Markings

Explosion protection marking
KSRV-M when installing terminals:KSRV-M when installing terminals::
0Ex ia IIC T6...T4 Ga X
1Ex eb IIC T6...T4 Gb
1Ex ia IIC T6...T4 Gb
Ex ib IIIC T85°...T135°С Db
Ex tb IIIC T85°...T135°С Db

KSRV-M when installing tires:KSRV-M when installing busbars::
1Ex eb IIC T6...T4 Gb
Ex tb IIIC T85°...T135°С Db

Housing (EX component)Box (EX component):
Ex eb IIC Gb U
Ex tb IIIC Db U
Marking of mining equipment
RP Ex eb I Mc
РВ Ex ib I Mb
PO Ex ia I Ma
RN1, RN2

Housing (EX component)Box (EX component):
Ex eb I Mc U
Degree of protection
IP66/IP67
IK10
Installation
Category I for firedamp and dust;
Category II for gas subgroups IIA, IIB, IIC, zones 0, 1, 2;
Category III for dust, explosive dust atmospheres
containing volatile particles, non-conductive and conductive dust;
Underground workings of mines and shafts, hazardous due to gas (methane), coal dust;
Non-hazardous zone of surface structures and open areas

Technical data

Ambient temperature, °C
-60...+40 (T6/T85°C)
-60...+60 (T5/T100°C)
-60...+70 (T4/T135°C)
-60...+85 (T4/T135°C)
-60...+85 (for mine explosion-proof and normal mine equipment)

For empty shells (Ex components):
-60...+150
Maximum voltage, V
~ 10000 / ~1000 / ⎓600
Maximum current, A
1500 / 800
Placement of cable glands
According to customer specifications. Cable entry holes can be made either on the sides of the box or in removable cable entry plates (usually required only in UK projects)
Grounding
2 ground cluminaires (internal and external) made of stainless steel
Cover fastening
On hinges, fixed with bolts (for KSRV-M111109 and KSRV-M171109 hinges are optional)
Mounting inside the case
2 or 4 mounting posts for panel mounting
Coating
Antistatic polymer-epoxy coating, friction-proof, spark-proof, resistant to working environments and ionizing radiation. Color RAL 7035
Sealing
Silicone rubber (in the lid groove)
Material
Sheet mild steel 1.2 mm (other thickness upon agreement)
Working position in space
Any
Protection class against electric shock
I
Climatic category
NF1 (as required NF4, NF5, T1, T2, T3, T5, HL5, MU1, MU2, MU3, MU4, W5 )

Design parameters

Drawing of explosion-proof boxes type KSRV-M made of mild steel

Overall and connection dimensions
Box size External dimensions, mm Fastening, mm Weight, kg
Method 1 Method 2
A B C G1 H1 G2 H2
KSRV-M111109 110 110 90 80 137 137 80 1,2
KSRV-M151512 150 150 120 120177177102 1,9
KSRV-M171109 176 116 95 14614320386 1,6
KSRV-M202012 200 200 120 170227227170 2,7
KSRV-M231815 230 180 150 200207257150 3,1
KSRV-M232315 230 230 150 200 257 257 200 3,6
KSRV-M271815 270 180 150 240 204 294 150 3,3
KSRV-M303012 300 300 120 270327327270 4,7
KSRV-M322312 320 230 120 290257347200 4,1
KSRV-M342315 340 230 150 310257367200 4,7
KSRV-M343415 340 340 150 310367367310 6
KSRV-M402315 400 230 150 370257427200 6,8
KSRV-M453415 450 340 150 420367477310 9,7
KSRV-M534315 530 430 150 500457557400 13,2
KSRV-M606025 600 600 250 570627627570 22,6
KSRV-M806030 800 600 300 770 627 827 570 30,4
KSRV-M1008030 1000 800 300 970 827 1027 770

If a large explosion-proof enclosure is required, it is possible to manufacture a module from several explosion-proof enclosures or a non-standard size according to the customer's requirements

Mounting panel
Overall dimensions of mounting panels
Mounting panel
by box type
Dimensions, mm
A B a b
KSRV-M111109 60 60 50 50
KSRV-M151512 100 100 90 90
KSRV-M171109 126 66 116 56
KSRV-M202012 150 150 140 140
KSRV-M231815 180 130 170 120
KSRV-M232315 180 180 170 170
KSRV-M322312 270 180 160 250
KSRV-M342315 290 180 270 160
KSRV-M343415 290 290 270 270
KSRV-M402315 350 180 330 160
KSRV-M453415 400 290 390 280
KSRV-M534315 480 380 470 370
KSRV-M606025 540 540 530 530
KSRV-M806030 540 740 520 720

Options

Options, accessories and versions
Marking
Aluminum alloy mounting panel
/ALP
Drainage ventilation devices
/DKUE
Lid lock
/ZAMOK
Design for operation at nuclear power plants
/MALAYA TECH
Marking of terminal cluminaires according to the customer's diagram
/MARK
Earthquake-resistant design
/MSHK-64
A plate with the customer's inscription
/NADPIS "_"
Stainless steel mounting plate
/NP
Viewing window according to customer's size
/O(SIZE)
Thermal heating for automation
/OBOGREV
Fixing the lid on hinges
/LOOP
Bolt with seal
/SEAL
Compliance with fire safety requirements
/POZHAR
Customer acceptance
/PRIEMKA
Non-explosion-proof design
/PROM
River execution
/RIVER
Mining normal design
/RN
Replacement plates for cable glands
/SPKV
The presence of jumpers between terminal cluminaires according to the customer's diagram
/SCHEME
Internal thermal insulation
/TEPLOISOLATSIA
Tropical version with insect protection
/TERMITY
Internal grounding busbar
/TIRE Z
Neutral busbar
/TIRE N
Device for combining cable screens
/SCREEN

Note: For the /BUS Z and /BUS H , the default configuration is buses with 2 x 16 mm2holes and a row of 6 mm2 holes( the number depends on the bus length). Busbars with different hole diameters can be installed upon agreement with the customer.

3D models

STP models
zip
Download
Revit models
zip
Download

Additional information

All KSRV-M explosion-proof enclosure covers, except for the KSRV-M111109 and KSRV-M171109, are supplied with hinges by default. Using hinged covers improves ease of installation, cable and wire connections, and subsequent maintenance.

External and internal stainless steel grounding cluminaires can be connected to a terminal block mounting rail, mounting plate, or grounding busbar. Grounding for cable glands is ensured through contact with the enclosure wall, eliminating the need for additional grounding continuity measures.

KSRV-M Mild Steel Explosion-Proof Junction Boxes

Maximum number of controls and indicators on the housing cover*
Box size Components with the "Exe" protection type
KSRV-M111109 1
KSRV-M151512 3
KSRV-M171109 3
KSRV-M202012 6
KSRV-M231815 7
KSRV-M232315 10
KSRV-M303012 16
KSRV-M322312 12
KSRV-M342315 12
KSRV-M343415 18
KSRV-M402315 13
KSRV-M453415 27
KSRV-M534315 39
KSRV-M606025 93
KSRV-M806030 127
*The number of installed elements depends on their dimensions and the sizes of the contact groups.
The exact number of elements and the housing size for a specific solution are specified when ordering.
Recommended maximum number of installed cable glands
Box size Side of
the box
Maximum permissible number of cable (pipe) entries
Cable entry sizes and thread types
01 1 2 3 4 5 6 7
G/M G/M G/M G/M G/M G/M G/M G/M
KSRV-M111109 A 2/2 2/2 2/2 1/1 1/1 - - -
B 2/2 2/2 2/2 1/1 1/1 - - -
KSRV-M151512 A 6 /6 6/6 4/4 2/3 1/1 1/1 1/1 -
B 7/7 6/6 5/5 3 /3 2/2 1/1 1/1 -
KSRV-M171109 A 4/5 4/5 3/3 3/3 2/2 - - -
B 2/2 2/2 2/2 1/1 1/1 - - -
KSRV-M202012 A 8/8 8/8 6/6 5/5 3/3 2/2 2/2 1/1
B 8/8 8/8 6/6 5/5 3/3 2/2 2/2 1/1
KSRV-M231815 A 16 /16 14 /14 10/12 7/7 5/5 3/3 1/1 1/1
B 13/13 12/12 8/8 5/5 4/4 2/2 2/2 1/1
KSRV-M232315 A 17/17 1515 11/12 7/7 5/5 2/2 1/1 1/1
B 1616 1515 10/11 7/7 5/5 2/2 1/1 1/1
KSRV-M303012 A 14/14 14/14 11/11 8/8 4/4 3/3 3/3 2/2
B 13/13 13/13 11/11 8/8 4/4 3/3 3/3 2/2
KSRV-M322312 A 19/19 15/15 10/11 77 4/4 2/2 2/2 1/1
B 14/14 12/12 8/8 5/5 3/3 1/1 1/1 1/1
KSRV-M342315 A 28 /28 24/24 17/17 11/11 7/7 4/4 3/3 2/2
B 19/19 16/16 12/12 7/7 5/5 2/2 2/2 1/1
KSRV-M343415 A 27/27 24/24 18/18 10/10 7/7 5/5 2/2 1/1
B 27/27 24/24 18/18 10/10 7/7 5/5 2/2 1/1
KSRV-M402315 A 34/34 30/30 21/22 13/13 9/9 5/5 4/4 2/2
B 19/19 16/16 12/12 7/7 5/5 2/2 2/2 1/1
KSRV-M453415 A 38/38 33/33 22/23 14/14 10/10 7/7 4/4 2/2
B 31/31 27/27 19/19 12/12 8/8 5/5 3/3 2/2
KSRV-M534315 A 46/46 41/41 29/30 17/17 12/12 8/7 5/5 3/3
B 39/39 34/34 25/25 15/15 10/10 7/7 4/4 1/1
KSRV-M606025 A 84/84 81/81 60/60 40/40 26/26 21/21 12/12 10/10
B 83/83 82/82 61/61 40/40 26/26 20/20 14/14 10/10
KSRV-M806030 A 135/135 135/135 99/99 69/69 44/44 38/38 27/27 14/14
B 100/100 100/100 73/73 49/49 35/35 24/24 19/19 10/10
Maximum permissible number of installed WDU terminals (excluding installation of cable glands)
Box size Maximum number of terminals (maximum number of terminals in one row)/nominal wire cross-section, mm2
2,5 4 6 10 16 35 50N 70N 120/150 240
KSRV-M111109 4 3 2 2 - - - - - -
KSRV-M151512 16 14 10 8 7 5 - - - -
KSRV-M171109 20 17 13 10 - - - - - -
KSRV-M202012 45(26) 37(22) 17 13 11 8 7 - - -
KSRV-M231815 44(32) 38(27) 28(21) 22(16) 18(13) 10 9 5 - -
KSRV-M232315 62(32) 52(27) 40(21) 30(16) 23(13) 10 9 8 - -
KSRV-M303012 117(46) 99(38) 75(29) 46(23) 38(19) 28(14) 12 11 - -
KSRV-M322312 96(50) 80(42) 60(32) 46(25) 36(21) 20(16) 13 12 - -
KSRV-M342315 104(54) 86(45) 64(34) 50(27) 40(23) 20(17) 15 13 - -
KSRV-M343415 152(54) 128(45) 96(34) 72(27) 46(23) 34(17) 15 13 - -
KSRV-M402315 130(65) 110(55) 80(42) 42(33) 36(28) 27(21) 18 160 4 -
KSRV-M453415 225(75) 189(63) 132(48) 104(39) 64(32) 48(24) 30(20) 26(19) 8 7
KSRV-M534315 364(90) 304(75) 184(58) 148(46) 120(38) 92(29) 54(25) 36(22) 14 12
KSRV-M606025 412(102) 344(85) 264(66) 212(52) 176(43) 132(32) 78(28) 50(25) 16 14
KSRV-M806030 568(102) 476(85) 364(66) 292(52) 244(43) 180(32) 112(28) 72(25) 16 14

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Contact Sales Department Download questionnaire Configure in CAD
Model Breakdown
KSRV-M 1X - ( 2X 3X - 2X 3X ) - 4X 5X ( 6X ) - 4X 5X ( 6X ) / 7X – TU 27.33.13-033-72453807-2017
1X - Size Code
2X - Number of terminal cluminaires
3X - Terminal cluminaire type
4X - Number of cable glands
5X - Cable entry type
6X - Input side Sides of cable entry locations
7X - Options, accessories and versions

Example: KSRV-M303012 (20C2-4C10-1PE10)-2KNV1N(B)-1KOV3N(A)-2KOV3N(V)-TU 3400-005-72453807-07

If you have difficulty choosing the box size based on the required characteristics, put the letter X instead of numbers after the box name.

Example: KSRV-M X (20C2-4C10-1PE10)-2KNV1N(B)-1KOV3N(A)-2KOV3N(V)-TU 27.33.13-033-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more