• Distribution and Terminal Boxes
  • Control and Automation Cabinets
  • Lighting Equipment
  • Control and Indicating Stations
  • Visual, Audible and Signaling Devices
  • Electrical Heating and Fans
  • Video Surveillance
  • IT equipment
  • Spark protection barriers and functional safety relays
  • Cable Glands, Conduits
  • Sockets, Plugs, Extension cords
  • Switches, Selectors Switches, Sensors
  • Control and Measuring Instruments
  • Cable/Pipe Transits
  • Electrical Components and Materials
Logo

Explosion-proof flexible reinforced cable elements of the MGM, MGMA series

Product Description

MGM/MGMA are explosion-proof, flexible, reinforced metal conduits made of highly corrosion-resistant stainless steel. They are used for laying cable routes between vibration-prone areas (electric motors, pumps, fans, etc.), as well as for protecting weak cable systems and fiber optics in hazardous areas. The metal conduit with metal braiding provides reliable protection and flexibility, while rotating fittings simplify installation and compensate for thermal and seismic movements.

Advantages

  • Rotating fittings facilitate installation, prevent cable twisting and compensate for axial displacement.
  • Extended operating temperature range (–60 °C…+150 °C), suitable for use in aggressive environments.
  • Effective dust- and moisture-proof design (up to IP66–IP68) with electromagnetic shielding (55 dB/1 MHz)

Frequently bought together

Compliance with standards

GOST 31610.0-2014 (IEC 60079-0:2011)
GOST IEC 60079-1-2013
GOST R IEC 60079-7-2012
GOST IEC 60079-31-2013
TR CU 012/2011

Certificates

Markings

Explosion protection marking
MGM:MGM:
Ex db IIB Gb U
Ex tb IIIC Db U
Ex eb IIC Gb U

MGMA:MGMA:
Ex db IIC Gb U*
Ex tb IIIC Db U
Ex eb IIC Gb U

*For metal hoses longer than 5 meters, separation using an explosion-proof fitting connector filled with compound is required. * For metal hoses longer than 5 meters, separation with a molded explosion-proof connector is required.
Degree of protection
IP66/IP67/IP68
IK08

Technical data

Ambient temperature, °C
-60...+150 (for a movable fitting)
-75…+250 (for a fixed fitting)
Thread
Code N conical inch NPT
Code M metric GOST 24705
Code R pipe conical GOST 6211-81
Code G pipe cylindrical GOST 6357-81
Fixed fittings
Stainless steel grade 08Х18Н10 according to GOST 5632-2014 (AISI 304) code N
Rotating fittings
Stainless steel grade 08Х18Н10 according to GOST 5632-2014 (AISI 304) code N
Flexible hose
Stainless steel grade 08Х18Н10 according to GOST 5632-2014 (AISI 304) code N
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

Flexible reinforced cable elements of the MGM series

Fitting 2 /Fitting 1 Fixed (outdoor) NN Fixed (internal) HB Movable (external) PN Movable (internal) PV
Fixed (outdoor) NN MGM..-NN-NN MGM..-NN-NV MGM..-NN-PN MGM..-NN-PV
Fixed (internal) HB MGM..-NV-NN MGM..-NV-NV MGM..-NV-PN MGM..-NV-PV
Movable (external) PN MGM..-PN-NN MGM..-Mon-NV MGM..-Mon-Mon MGM..-PN-PV
Movable (internal) PV MGM..-PV-NN MGM..-PV-NV MGM..-PV-PN MGM..-PV-PV
Thread diameter of end fittings depending on the size of the metal hose
Threaded holes
Standard size 1 2 3 4 5 6 7 8 10
Thread diameter R GOST 6211-81 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 4"
Thread diameter M metric GOST 24705 M20 M25 M32 M40 M50 M63 M75 M90 M100
Min. hose length, dm 3 3 3 4 5 5 7 7 7
Explosion protection marking depending on the length of the metal sleeve*
Length, dm** Version
from to
3 50 Ex db IIC Gb U
3 100 Ex db IIB Gb U

*Other hose lengths and designs are available upon request.
**When selecting the minimum length of the metal hose, please also refer to the table "Thread diameter of end fittings depending on the size of the metal hose."

Standard size of metal hose
Standard size Minimum bending radius Nominal bore diameter
Code inch mm mm
1 1/2" 140 12
2 3/4" 170 20
3 1" 190 25
4 1 1/4" 260 32
5 1 1/2" 300 40
6 2" 320 50
7 2 1/2" 350 65
8 3" 360 80
10 4" 380 100
Hose fitting type Description
Fixed (outdoor) NN Fixed (outdoor) NN
Fixed (internal) HB Fixed (internal) HB
Movable (external) PN Movable (external) PN
Movable (internal) PV Movable (internal) PV

Options

Options, accessories and versions
Marking
Locknut (cylindrical and metric threads)
/KG
Marine version
/MORE
Non-explosion-proof design
/PROM
External sealing ring to maintain tightness (cylindrical and metric threads)
/UKF

Additional information

INCORRECT INSTALLATION DESCRIPTION CORRECT INSTALLATION
Do not pull the flexible element of the MGM - unwind it carefully Do not stretch the flexible element of MGM, MGMA - unwind it carefully Do not pull the flexible element of the MGM - unwind it carefully
Do not twist the flexible element of the MGM - install it without twisting Do not twist the flexible element MGM, MGMA - install it without twisting Do not twist the flexible element of the MGM - install it without twisting
Try to ensure that the length of the flexible element of the MGM is not too short	Try to ensure that the length of the flexible element MGM, MGMA is not too short Try to ensure that the length of the flexible element of the MGM is not too short
Avoid excessive bending of the flexible element of the MGM, use fittings 	Avoid excessive bending of the flexible element MGM, MGMA, use fittings Avoid excessive bending of the flexible element of the MGM, use fittings
Do not move the flexible element of the MGM across the surface being installed, move it only along the axis	Do not move the flexible element MGM, MGMA across the surface being installed, move it only along the axis Do not move the flexible element of the MGM across the surface being installed, move it only along the axis
Try to prevent the flexible element of the MGM from bending, use a template	Try to ensure that the flexible element of the MGM, MGMA does not bend, use a template Try to prevent the flexible element of the MGM from bending, use a template
s71.tif If there is a strong movement along the axis, do not install the flexible element MGM, MGMA in a straight line, install it in a U-shaped bend s7_7.tif
Avoid twisting when equipment is not in line, install only in one plane Avoid twisting when equipment is not in line, install only in one plane Avoid twisting when equipment is not in line, install only in one plane
Avoid bending the flexible element of the MGM when suspended, use a reel Avoid bending the flexible element of the MGM, MGMA in a suspended state, use a reel Avoid bending the flexible element of the MGM when suspended, use a reel
Avoid excessive bending of the ends of the flexible element of the MGM, use fittings Avoid excessive bending of the ends of the flexible element MGM, MGMA, use fittings Avoid excessive bending of the ends of the flexible element of the MGM, use fittings
Avoid oscillations in the direction of the axis, install the flexible element of the MGM vertically to the direction of movement Avoid oscillations in the direction of the axis, install the flexible element MGM, MGMA vertically to the direction of movement Avoid oscillations in the direction of the axis, install the flexible element of the MGM vertically to the direction of movement
Do not allow vibration from different directions on one flexible element of the MGM - install several hoses Do not allow vibrations from different directions on one flexible element of MGM, MGMA - install several hoses Do not allow vibration from different directions on one flexible element of the MGM - install several hoses
Don't let the flexible MGM element move in only one direction - move it to the center to distribute the movement in both directions Do not allow the flexible element of the MGM, MGMA to move in only one direction - move it to the center to distribute the movement in both directions Don't let the flexible MGM element move in only one direction - move it to the center to distribute the movement in both directions
Avoid axial vibrations, install the flexible element of the MGM vertically to the direction of movement Avoid axial vibrations, install the flexible element MGM, MGMA vertically to the direction of movement Avoid axial vibrations, install the flexible element of the MGM vertically to the direction of movement
Avoid lateral vibration - install the flexible element of the MGM at an angle of 90° Avoid lateral vibrations - install the flexible element MGM, MGMA at an angle of 90° Avoid lateral vibration - install the flexible element of the MGM at an angle of 90°
Avoid bending - bending of the flexible element of the MGM and oscillation must be in the same plane Avoid bending - bending of the flexible element of the MGM and oscillation must be in the same plane Avoid bending - bending of the flexible element of the MGM and oscillation must be in the same plane
Do not allow excessive bending of the ends of the flexible element of the MGM, use fittings Do not allow excessive bending of the ends of the flexible element MGM, MGMA, use fittings Do not allow excessive bending of the ends of the flexible element of the MGM, use fittings
Do not install flexible MGM elements of greater length - install flexible MGM elements of precise length Do not install flexible MGM, MGMA elements of greater length - install flexible MGM, MGMA elements of the exact length Do not install flexible MGM elements of greater length - install flexible MGM elements of precise length
Try to keep the distance from being too large, use precise dimensions Try to keep the distance from being too large, use precise dimensions Try to keep the distance from being too large, use precise dimensions
Do not allow bending during angular vibrations; all movements of the flexible element of the MGM are only along the axis Do not allow bending during angular vibrations; all movements of the flexible element MGM, MGMA are only along the axis Do not allow bending during angular vibrations; all movements of the flexible element of the MGM are only along the axis
Do not drag the flexible MGM element across the floor without some protection. Avoid damage by using a protective mat Do not drag the flexible MGM or MGMA element across the floor without some form of protection. Avoid damage by using a protective mat Do not drag the flexible MGM element across the floor without some protection. Avoid damage by using a protective mat

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Model Breakdown
1X - 2X 3X 4X 5X - 6X 7X 8X 9X - 10X / 11X – TU 27.33.13-031-72453807-2017
1X - Type of metal hose: MGMA (length up to 50 dm); MGM (length up to 50 dm)
2X - Fitting type 1: NN; HV; PN; PV
3X - Thread size
4X - Thread type
5X - Material (for rotating fittings PN, PV): Stainless steel - H
6X - Fitting type 2: NN; NV; PN; PV
7X - Thread size
8X - Thread type
9X - Material (for rotating fittings PN, PV): Stainless steel - H
10X - Length of metal sleeve, dm
11X - Options, accessories and versions

Example: MGMA-PN1RN-PV2RN-40-TU 27.33.13-031-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Read more
193149, Russia, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1

Moscow

Sales office

Read more
123112, Russia, Moscow, Presnenskaya embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15

Kazan

Sales office

Read more
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110