Explosion-Proof Terminal Cluminaires (Terminal Blocks) and Grounding Elements

Explosion-Proof Terminal Cluminaires (Terminal Blocks) and Grounding Elements

Explosion-proof terminal cluminaires (terminal blocks)

CONSTRUCTION MATERIALS

Insulation material:

ZAVOD GORELTEX CO. LTD. uses terminal cluminaires that primarily utilize polyamide as the insulating material for current-carrying parts. Polyamide has been tested by nearly all international laboratories and has proven its worth in terminal cluminaires for 40 years. Excellent stability against stray currents allows for shorter spark gaps and stray current intervals, which in turn allows for the creation of compact units.

Moisture absorbed from the environment, on average up to 2.5%, binds to the chemical structure of polyamide, giving it optimal elasticity and fracture resistance.

ZAVOD GORELTEX CO. LTD. strives to supply terminal cluminaires made of modified polyamide, which is free of halogens, fluorocarbons, silicones, asbestos, cadmium, and formaldehyde. Polyamide is a corrosion-resistant, flame-retardant material with self-extinguishing properties and thermal stability under long-term temperature loads (upper limit of +200°C, lower limit of -60°C).

Basic stabilization provides sufficient protection against ozone and ultraviolet rays for many years. Weather resistance is also excellent. Polyamide has proven itself in tropical conditions. Parts molded from polyamide are resistant to termites and do not provide sources of oxygen or other biogenic elements that promote microbial growth. Anaerobic soil bacteria, mold, and enzymatic fungi have no negative impact on this material. This insulation material exhibits exceptional stability against flammable substances, primarily oils and fats, as well as cleaning agents such as alcohol, freon, and tetrachlorocarbons. The material's acid resistance depends on the type of acid and its concentration (information available upon request).

The terminal cluminaires can withstand a load of 100N

Contact materials:

Klemsan, SUPU, Phoenix, Weidmuller use copper-zinc alloys or electrical copper with a tin-lead coating in the production of contacts.

All contact materials have good chemical resistance and are inert to stress corrosion cracking, guaranteeing long-term corrosion protection.

The spring material used for the cluminaireing spring is high-quality, carefully tested austenitic chromium-nickel steel with high tensile strength, which has demonstrated excellent corrosion resistance over many years of service. It is resistant to sea air, natural gas, and industrial gases such as hydrogen sulfide and sulfur dioxide. Decades of use of these materials have revealed no cases of contact corrosion between the chromium-nickel spring steel and other contact materials, including the connected copper conductors.

All terminal cluminaires received by us undergo additional control tests.

It is recommended to carry out installation at temperatures not lower than -40°C.

TERMINAL BLOCK
SINGLE-CORE CONDUCTOR CROSS-SECTION , MM2
SECTION OF A MULTI-CORE CONDUCTOR WITH A TIP, MM2
TYPE
EXECUTION OF EXE
RATED CURRENT, AND FOR EXE EXECUTION
RATED CURRENT, A
NOMINAL VOLTAGE, V FOR EXE VERSION
NOMINAL VOLTAGE, V
DIN RAIL TYPE
MANUFACTURER
DIMENSIONS
SPRING
SCREW
TH35-7.5
TH35-15
G32
TH15-5.5
KLEMSAN
SUPU
PHOENIX
Weidmuller
WIDTH, MM
LENGTH, MM
HEIGHT, MM
AKZ/AKE 1.5 0,5-2,5 0,5-1,5 X X 17 17 220 220 X X 5,1 24,8 24
AKZ/AKE 2.5 0,5-4 0,5-2,5 X X 24 24 220 220 X X 5,1 25,5 26,3
AKZ/AKE 4 0,5-6 0,5-4 X X 28 28 275 275 X X 6,1 28,5 29
AVK 10 0,5-16 0,5-10 X X 50 57 630 630 X X X 10 44,2 44,6
AVK 150 35-150 50-150 X X 249 309 1000 1000 X X X 31 95,5 107,5
AVK 16 RD 1,5-25 1,5-16 X X 67 76 630 750 X X X 12 52,8 58,6
AVK 2.5 RD 0,2-4 0,25-2,5 X X 20 24 630 750 X X X 5 44,2 44,6
AVK 240 50-240 70-185 X X 337 415 1000 1000 X X X 36 95,5 115
AVK 35 RD 1,5-50 1,5-35 X X 111 125 630 750 X X X 16 52,8 58,6
AVK 4 RD 0,2-6 0,25-4 X X 25 32 680 800 X X X 6 44,2 44,6
AVK 50 16-70 25-50 X X 133 150 800 1000 X X X 20 95,2 77
AVK 6 0,2-10 0,25-6 X X 36 41 630 630 X X X 8 44,2 44,6
AVK 70 RD 16-70 16-70 X X 162 192 630 1000 X X X 22 94,6 81
AVK 95 25-95 35-95 X X 193 232 1000 1000 X X X 25 95,2 90
MSB 2.5 0,08-4 0,08-2,5 X X 24 24 800 800 X X 5,2 32 22
MT 1.5 0,14-1,5 0,14-1,5 X X 17 17 275 400 X X 4,2 22 23,5
MUT 2.5 0,2-4 0,2-2,5 X X 24 24 352 500 X X 5,2 29,9 33,3
MUT 4 0,2-6 0,2-4 X X 32 32 352 500 X X 6,2 29,9 33,3
MVK 2.5 0,2-4 0,25-2,5 X X 20 24 400 400 X X 5 27,7 33,75
MVK 4 0,2-6 0,25-4 X X 28 32 400 400 X X 6 27,7 33,75
MYK 2.5 0,08-4 0,14-2,5 X X 20 24 320 750 X X 5 33 39,1
PYK 1.5 0,34-2,5 0,5-1,5 X X 15 17 500 800 X X X 4,2 52 37,8
PYK 10 0,5-16 0,5-10 X X 50 57 800 800 X X X 10 75,4 52
PYK 2.5 0,34-4 0,25-2,5 X X 21 24 800 800 X X X 5 53,4 43
PYK 2.5 E 0,34-4 0,25-2,5 X X 21 24 630 800 X X X 5 64,8 43
PYK 2.5-2 F 0,34-4 0,25-2,5 X X 18 24 400 500 X X X 5 75,3 62,9
PYK 4 0,34-6 0,34-4 X X 28 32 800 800 X X X 6 55,9 44
PYK 4 E 0,34-6 0,34-4 X X 26 32 800 800 X X X 6 70,8 44
PYK 4-2 F 0,34-6 0,34-4 X X 28 32 500 500 X X X 6 86,8 65,6
PYK 6 0,5-10 0,5-6 X X 36 41 800 800 X X X 8 65,6 46,2
SSK 0525 KER-EX 0,2-4 0,2-2,5 X X 24 24 440 440 X X 6,2 38 44,5
SSK 110 KER-EX 0,5-10 0,5-10 X X 41 41 440 440 X X 8,4 38 50,5
SSK 116 KER-EX 0,5-16 0,5-16 X X 57 57 440 440 X X 10,4 38 50,5
SSK 135 KER-EX 1-35 1-35 X X 125 125 440 440 X X 15,3 53 63
ST 1.5 0,08-1,5 0,08-1,5 X X 17 17 440 500 X X X 4,2 48,5 36,5
ST 10 0,2-16 0,25-10 X X 57 57 690 1000 X X X 10 71,5 50,5
ST 16 0,2-25 0,25-16 X X 76 76 690 1000 X X X 12 80 51
ST 2.5 0,08-4 0,08-2,5 X X 24 24 800 800 X X X 5,2 48,5 36,8
ST 2.5-TWIN 0,08-4 0,08-2,5 X X 24 24 440 440 X X X 5,2 60,5 36,5
ST 35 2,5-35 2,5-35 X X 125 125 690 1000 X X X 16 100 59
ST 4 0,08-6 0,08-4 X X 32 32 690 800 X X X 6,2 56 36,8
ST 4-TWIN 0,08-6 0,08-4 X X 32 32 440 440 X X X 6,2 71,5 36,5
ST 6 0,2-10 0,25-6 X X 41 41 690 1000 X X X 8,2 69,5 43,5
STS 2.5 0,08-4 0,08-2,5 X X 24 24 440 440 X X X 5,2 50,8 43
STS 2.5-TWIN 0,08-4 0,08-2,5 X X 24 24 440 440 X X X 5,2 64,5 43
STS 4 0,08-6 0,08-4 X X 32 32 440 440 X X X 6,2 50,8 43
STS 4-TWIN 0,08-6 0,08-4 X X 32 32 440 440 X X X 6,2 64,5 43
STTB 1.5 0,08-1,5 0,08-1,5 X X 17 17 440 440 X X X 4,2 67,5 47,5
STTB 2.5 0,08-4 0,08-2,5 X X 24 24 440 440 X X X 5,2 67,5 47,5
STTB 4 0,08-6 0,08-4 X X 32 32 440 440 X X X 6,2 83,5 47,5
TA2.5-3 0,2-2,5 0,2-1,5 X X 24 24 440 440 X X X 5 50 43,5
TC1.5-2 0,2-1,5 0,2-1,5 X X 17 17 500 500 X X X 4,2 48,2 36,8
TC1.5-3 0,2-1,5 0,2-1,5 X X 17 17 500 500 X X X 4,2 60,2 36,8
TC10-2 0,2-16 0,2-10 X X 57 57 1000 1000 X X X 10,2 71,5 50,4
TC16-2 0,2-25 0,25-16 X X 76 76 1000 1000 X X X 12,2 80 51,5
TC2.5-2 0,2-4 0,2-2,5 X X 24 24 800 800 X X X 5,2 48,2 36,8
TC2.5-3 0,2-4 0,2-2,5 X X 24 24 800 800 X X X 2 60,2 36,8
TC35-2 2,5-35 2,5-35 X X 125 125 1000 1000 X X X 16,1 100 59
TC4-2 0,2-6 0,2-4 X X 32 32 800 800 X X X 6,2 56,2 36,8
TC4-3 0,2-6 0,2-4 X X 32 32 800 800 X X X 6,2 71,8 36,8
TC6-2 0,2-10 0,2-6 X X 41 41 1000 1000 X X X 8,2 69,5 43,5
TCD1.5-2 0,2-1,5 0,2-1 X X 16 16 440 440 X X X 3,5 68 43,4
TCD2.5-2 0,2-4 0,2-2,5 X X 22 22 440 440 X X X 5,2 68 47,5
TU10-2 0,5-16 0,5-10 X X 57 57 1000 1000 X X X 10,2 47,6 46,2
TU150-2 35-150 35-150 X X 309 309 1000 1000 X X X 31 100,1 108
TU16-2 1,5-25 1,5-16 X X 76 76 1000 1000 X X X 12,2 52,8 54,4
TU2.5-2 0,2-4 0,25-2,5 X X 24 24 1000 1000 X X X 5,2 47,6 46,2
TU240-2 70-240 70-240 X X 415 415 1000 1000 X X X 31 100,1 121
TU35-2 1,5-50 1,5-35 X X 125 125 1000 1000 X X X 16 62,2 65,1
TU4-2 0,2-6 0,25-4 X X 32 32 1000 1000 X X X 6,2 47,6 46,2
TU50-2 16-70 16-50 X X 150 150 1000 1000 X X X 20,4 70,7 76
TU6-2 0,2-10 0,25-6 X X 41 41 1000 1000 X X X 8,2 47,6 46,2
TU70-2 25-70 25-70 X X 192 192 1000 1000 X X X 20 78,6 77
TU95-2 25-95 25-95 X X 232 232 1000 1000 X X X 25 82,9 90
UKH 150 35-150 35-150 X X 309 309 1000 1000 X X 31 100 118,5
UKH 240 70-240 70-240 X X 415 415 1000 1000 X X 36 100 131,5
UKH 50 16-70 16-50 X X 150 150 1000 1000 X X 20 70,5 83,5
UKH 70 16-95 16-70 X X 180 180 880 880 X X 20,3 70,5 80
UKH 95 25-95 25-95 X X 232 232 1000 1000 X X 25 83 97,5
UT 10 0,5-16 0,5-10 X X 57 57 1000 1000 X X X 10,2 46,9 47,5
UT 16 1,5-25 1,5-16 X X 76 76 690 1000 X X X 12 52,8 54,8
UT 2.5 0,14-4 0,14-2,5 X X 24 24 1000 1000 X X X 5,2 46,9 47,5
UT 35 1,5-50 1,5-35 X X 125 125 690 1000 X X X 16 60,2 65,7
UT 4 0,14-6 0,14-4 X X 32 32 1000 1000 X X X 6,2 46,9 47,5
UT 6 0,2-10 0,2-6 X X 41 41 1000 1000 X X X 8,2 46,9 47,5
WDU/WPE 10 1,5-10 1,5-10 X X 57 57 440 440 X X X 10 60 47
WDU/WPE 120/150 16-150 16-150 X X 265 265 440 440 X X X 32 132 118
WDU/WPE 16 1,5-25 1,5-16 X X 76 76 440 440 X X X 12 60 63
WDU/WPE 2.5 0,14-4 0,14-2,5 X X 24 24 440 440 X X X 5 60 47
WDU/WPE 240 70-240 70-240 X X 350 350 440 440 X X X 36 100 124
WDU/WPE 35 2,5-50 2,5-35 X X 115 115 440 440 X X X 16 60 63
WDU/WPE 4 0,14-6 0,14-4 X X 32 32 440 440 X X X 6 60 47
WDU/WPE 50N 4-70 4-50 X X 126 126 440 440 X X X 18,5 71 80
WDU/WPE 6 0,14-6 0,14-6 X X 41 41 440 440 X X X 8 60 47
WDU/WPE 70N/35 10-95 10-70 X X 184 184 440 440 X X X 20,4 75 90
ZDU/ZPE 1.5 0,5-1,5 0,5-1,5 X X 15 15 440 440 X X X 3,5 51,5 37
ZDU/ZPE 10 1,5-16 1,5-10 X X 50 50 440 440 X X X 10 73,5 50,5
ZDU/ZPE 16 1,5-25 1,5-16 X X 63 63 440 440 X X X 12 82,5 51,5
ZDU/ZPE 2.5 0,5-4 0,5-2,5 X X 20 20 440 440 X X X 5 59,5 39
ZDU/ZPE 35 2,5-35 2,5-35 X X 110 110 440 440 X X X 16 100 60
ZDU/ZPE 4 0,5-6 0,5-4 X X 28 28 440 440 X X X 6 62 43,5
ZDU/ZPE 6 0,5-10 0,,5-6 X X 36 36 440 440 X X X 8 65 45,5


ALGORITHM FOR SELECTING TERMINAL CLAMPS

- For products with Exe protection, the terminal cluminaires must be of Exe design, for Exia products – Exia design.

- The terminal cluminaire must correspond to the wire cross-section (for a spring terminal block – the cluminaire type).

- It is necessary to take into account the maximum voltage and current of the connected conductor.

- It is necessary to take into account the type of DIN rail (especially when it is necessary to install different terminal cluminaires next to each other).

Maximum dissipated power of Exe products.

Ex "e" enclosures provide a table for each enclosure size, indicating the maximum number of terminal blocks or conductors for the specified current value and cross-section, e.g. "arrangement method".

For small cross-sections, the dissipated power depends on the wire size, since the resistance of a high-quality terminal block is negligible. Therefore, the number in the table actually represents the number of wire pairs that can be connected in the junction box. For example, a user may decide, based on the manufacturer's datasheet, to install terminal blocks that allow the connection of a cable with a maximum wire cross-section of 4 mm²,but use a cross-section of 2.5 mm².In this case, it is very important to understand that the value in the table does not refer to the number of terminals with a maximum cross-section of 4 mm²,but indicates the number of connected pairs of wires with a cross-section of 2.5mm².

Alternatively, Ex "e" enclosures are marked with a maximum dissipated power (MDP) value, which is used to calculate the possible number of terminals that can be installed. Based on the installed current and the total resistance of the cable and terminal, the user or manufacturer calculates the dissipated power per terminal block. This figure, multiplied by the number of terminals, must always be less than the maximum dissipated power value indicated on the enclosure.

For boxes with Exe protection, it is recommended to use terminal cluminaires with a copper-zinc alloy conductor, as they have the lowest resistance and, accordingly, power dissipation.

Exia terminals

Exia terminals

There are no special requirements for Exia terminal cluminaires, as they are designed for limited currents and voltages. Protection is provided by intrinsically safe barriers. Blue RAL 5015 is used to mark intrinsically safe circuits.

Continuous monitoring of the performance of intrinsically safe barriers, as well as the integrity of cables carrying intrinsically safe circuits, is required. It is important that intrinsically safe circuits do not intersect with non-intrinsically safe circuits. Exia terminal blocks must be located at least 50 mm away from terminal blocks carrying non-intrinsically safe circuits. The price of intrinsically safe barriers directly depends on their reliability. Avoid purchasing low-quality products.

The terminals are protected from vibration.

Screw EXE terminal

SCREW EXE TERMINALThe cage body and cluminaireing screw create the high cluminaireing force required to ensure reliable and long-lasting contact. The cluminaireing mechanism presses the connected wire against the busbar. This creates a sealed connection between the wire and the terminal, ensuring resistance to shock and vibration.

The terminals are vibration-resistant. When the cluminaireing screw is tightened, the steel body of the cluminaireing terminal deforms, and the upper cluminaireing tongue moves away from the cage body. The upper cluminaireing tongue ensures a constant cluminaireing force, acting similarly to a spring washer.

The spring mechanism securely holds the connected wire, eliminating the need to tighten the screws during operation.

Spring EXE cluminaire

Spring terminals separate the functions of mechanical cluminaireing and electrical contact. The spring presses the wire against the busbar. Spring terminals are maintenance-free.

SPRING EXE CLAMPSpring terminals separate the functions of mechanical cluminaireing and electrical contact. The spring presses the wire against the conductive busbar. Spring terminals are maintenance-free.

Using spring terminals significantly reduces installation time compared to screw connections. Spring terminals are not recommended for mining, marine, military, mobile, and medium-duty equipment.

Spring-plug connection

Spring-loaded plug connection

In direct plug-in terminals, a single-core insulated wire is inserted into the terminal like a measuring instrument plug. Installation is extremely quick and easy, requiring no tools. The contact in the plug-in terminal is reliable, sealed, and vibration-resistant. When using a sleeve cable lug, a stranded flexible wire can be easily connected to the plug-in terminal. The spring and guide cage ensure that the wire is pressed against the copper busbar with a force significantly greater than that of traditional spring-loaded terminals. Due to their compact size, spring-loaded terminals are used in terminal boxes for pipe wiring.
The use of spring-loaded terminals significantly reduces installation time compared to screw-type connections. Spring-loaded terminals are not recommended for mining, marine, military, mobile, and medium-sized engineering equipment.

Spring-plug connection

Application of tips

When using ferrules, the stranded wire must always be tightly crimped to prevent gas ingress and ensure a vibration-resistant, reliable connection. Naturally, only high-quality wires, ferrules, and crimping tools should be used for explosion-proof electrical equipment. Even a good tool cannot function properly if the ferrule is incorrectly selected for the cable. It's also possible that both the wire and ferrule are of high quality, but their incorrect selection prevents a high-quality crimp. Sometimes, manufacturing variations in the wire and ferrule overlap, resulting in a poor-quality crimp.

IMPORTANT TO KNOW: CLAMPS AND CONNECTIONS DO NOT CONFORM TO PROTECTION TYPE "e"

If contact is broken or resistance increases on the terminal cluminaires due to improper installation or corrosion during operation, devices with protection type "e" become HAZARDOUS . Electrical connections in Exe equipment must be periodically checked and maintained in proper condition. The explosion protection level for Exe equipment in the Russian Federation is "2" (equivalent to Zone 2). In Europe, ATEX allows this equipment to be used in Zone 1. The use of equipment with protection type "e" in Zone 1 in the Russian Federation is partially restricted.

CLAMPS AND CONNECTIONS NOT CONFORMING TO VIEW PROTECTION CLAMPS AND CONNECTIONS NOT CONFORMING TO VIEW PROTECTION
As a result of improper installation or corrosion during operation, devices with protection type “e” become DANGEROUS for use.

Additional information

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more