ZKG-N Stainless Steel Explosion-Proof Heated Instrument Enclosures

Product Description

ZKG-N heated instrument enclosures are used to protect control and measuring instruments from the negative effects of low temperatures, dust, chemicals, mechanical damage, and unauthorized access. These cabinets are ideal for outdoor installations and unheated spaces, housing various explosion-proof equipment, and also for use as control cabinets and control panels when installed in hazardous areas.

The robust stainless steel enclosure of the thermal cabinet protects control and measuring instruments from mechanical damage, while the high IP66 protection rating helps protect equipment from dust and moisture.

The heating cabinet can be equipped with various heating systems (electric, water, and steam), ensuring comfortable operating conditions for control and measuring instruments. An additional layer of flexible thermal insulation ensures long-term heat retention.


A unique design feature is the inclusion of removable panels, specifically designed for easy installation of cable glands. Drilling holes and installing cable glands can be performed on the workbench.

ZKG-N heated instrument enclosures are manufactured in 2 standard sizes; upon customer request, non-standard sized housings and removable plates can be manufactured.

Advantages

  • Resistant to aggressive environments, alkalis, and drops of sulfuric and hydrochloric acid. Various heating types are available. Inspection windows can be installed according to customer specifications. Removable plates for cable glands are available. Models with classic, diagonal, and split openings are available. A lid lock is optional.
  • Custom made

Frequently bought together

Compliance with standards

TR CU 012/2011
GOST 14254-2015
GOST 31441.1-2011
GOST 31610.0-2014 (IEC 60079-0:2011)
GOST R IEC 60079-7-2012
GOST R IEC 60079-31; GOST 30852.8-2002
GOST IEC 60079-1-2011
GOST 30852.10-2002 (IEC 60079-11:1999)
GOST R IEC 60079-18-2012

Certificates

TU 27.12.23-060-72453807-2017

Markings

Explosion protection marking

With electric heating:With electric heating:
1Ex de IIC T3 Gb (GTG-MODULEGTG-MODULE)
1Ex e II T3 Gb X (GTG-RADIATOR2GTG-RADIATOR2)
1Ex e II T3 Gb X (GTG-PLASTINA1GTG-PLASTINA1)

With water and steam heating:Water and steam heating:
II Gb IIC T3 X (heating with water/steam no higherheating with water / steam not higher 195°C)
II Gb IIC T4 X (heating with water/steam no higherheating with water / steam not higher 130°C)
II Gb IIC T5 X (heating with water/steam no higherheating with water / steam not higher 95°C)
II Gb IIC T6 X (water heating no higherHeating with water is not higher 80°C)

Without heating:Without heating:
II Gb IIC / II Gb IIB

Ex-component:Ex component:
Ex e IIC Gb U
Ex tb IIIC Db U
II Gb IIC or II Gb IIB

The Ex marking of an instrument cabinet is determined based on the installed explosion-proof components. The temperature class and maximum surface temperature in the explosion protection marking depend on the temperature class and maximum surface temperature of the installed equipment. Ex marking of I&C cabinet is formed taking into account Ex components installed. The temperature class and maximum surface temperature in explosion protection marking depend on the temperature class and maximum surface temperature of the equipment installed.

Degree of protection
IP66
IK08
Installation
Category II for gas subgroups IIA, IIB, IIC, zones 1, 2;
Category III for dust IIIA, IIIB, IIIC, zones 21, 22

Technical data

Ambient temperature, °C
-60...+85
Maintained temperature inside the cabinet, °C
-40...+60 (depending on the heating system used)
Maximum voltage, V
~400 (50/60Hz)
Maximum current, A
415
Placement of cable glands
According to customer specifications
Grounding
3 ground cluminaires (2 internal and 1 external) made of stainless steel
Cover fastening
Hinged, secured with stainless steel quick-release cluminaires.
Opening types: classic, diagonal, and split.
Mounting inside the case
2 mounting panels
Sealing
Silicone rubber (in the lid groove)
Material
Stainless steel grade 08Kh18N10 according to GOST 5632-2014 (AISI 304), resistant to high temperatures and corrosion. Metal thickness: 1.5…2 mm
Housing fastening
Floor-standing, wall-mounted, tripod
Protection class against electric shock
I
Climatic category
U1...5, HL1...5, NF1...5, O1...5, MU1, V1...5

Design parameters

Case size Overall dimensions, mm
External dimensions Internal dimensions
A IN WITH a b c
ZKG-N363638 360 365 385 357 362 382
ZKG-N464939 460 490 390 457 487 387
ZKG-N475142 470 510 420 467 507 417
ZKG-N476147 470 610 470 467 607 467
ZKG-N584939 585 490 390 582 487 387
ZKG-N597568 595 750 680 592 747 677
ZKG-N686868 680 680 680 677 677 677
ZKG-N706555 700 650 550 697 647 547
ZKG-N755760 750 570 600 747 567 597
ZKG-N846147 840 610 470 837 607 467
ZKG-N867676 860 760 760 857 757 757
ZKG-N976556 970 650 560 967 647 557
ZKG-N1016647 1010 660 470 1007 657 467

Standard arrangement of removable plates

At customer request, we manufacture housings and removable plates of non-standard sizes.

Options

Options, accessories and versions
Marking
Stainless steel grade 03Х17Н13М2 according to GOST 5632-2014 (316L)
/316L
Lid lock
/ZAMOK
A plate with the customer's inscription
/NADPIS "_"
Viewing window according to customer's size
/O(SIZE)
Thermal heating for automation
/OBOGREV
Heating with water or steam
/STEAM
Customer acceptance
/PRIEMKA
Non-explosion-proof design
/PROM
Installation of a special busbar (mounting panel by default)
/TIRE
Internal grounding busbar
/TIRE Z

Note: For the /BUS Z , the default configuration is buses with 2 x 16 mm2 holesand a row of 6 mm2 holes( the number depends on the bus length). Busbars with different hole diameters can be installed upon customer agreement.

Additional information

Electric heating

To heat the internal volume of the protective housings of the ZKG, it is recommended to use a module of GTG-MODULE heaters, an explosion-proof heater GTG-RADIATOR2 and explosion-proof heating plates GTG-PLASTINA1.

Compliance of the required heating power and the housing used
Name of the corps Heating power, W
ZKG-N 476147 150
ZKG-N 976556 300
Explosion protection marking for electric heaters
Electric heater Explosion protection marking
Explosion-proof module from GTG-MODULE heaters 1Ex de IIC T3 Gb
Explosion-proof heater GTG-RADIATOR2 1Ex e II T3 Gb X
GTG-PLASTINA1 Explosion-Proof Heating Plates 1Ex e II T3 Gb X

Marking

The marking applied to the boxes includes the following information:
- trademark of the manufacturer;
- type of product;
- serial number and year of manufacture;
- explosion protection marking;
- permissible ambient temperature.

When heating with water or steam only:
– the operating temperature (Ts) is indicated on the nameplate;
– an additional nameplate is installed with the value of the coolant temperature and its pressure.

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Model Breakdown
ZKG-N - 1X / 2X / 3X – TU 27.12.23-060-72453807-2017
1X - Case size code
2X - Mounting type: wall mount - C; floor mount - P; pole mount - W
3X - Options, accessories and versions

Example: ZKG-N 476147/С/OBOGREV/О2515/ZAMOK – ТU 27.12.23-060-72453807-2017

If you have difficulty choosing the box size based on the required characteristics, put the letter X instead of numbers after the box name.

Example: ZKG-N H/С/OBOGREV/ОH/ZAMOK – ТU 27.12.23-060-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more