• Distribution and Terminal Boxes
  • Control and Automation Cabinets
  • Lighting Equipment
  • Control and Indicating Stations
  • Visual, Audible and Signaling Devices
  • Electrical Heating and Fans
  • Video Surveillance
  • IT equipment
  • Spark protection barriers and functional safety relays
  • Cable Glands, Conduits
  • Sockets, Plugs, Extension cords
  • Switches, Selectors Switches, Sensors
  • Control and Measuring Instruments
  • Cable/Pipe Transits
  • Electrical Components and Materials
Logo

Explosion-proof self-regulating heating cable GTG-KABEL1-130

Product Description

Flexible heating cable with self-regulating temperature is designed for heating and maintaining the process temperature of automation objects, tanks, pipelines, and any other objects that require additional protection from freezing and icing.

At low temperatures, the heating element material contracts, creating multiple conductive paths of carbon material, thereby reducing electrical resistance. When an electric current passes through the heating element, thermal energy is released.

In warmer sections of explosion-proof heating cable, the heating element material expands, reducing the number of conductive paths. The electrical resistance of the heating element material increases, resulting in reduced heat generation.

Explosion-proof flexible high-temperature heating cable with high power and self-regulating temperature GTG-KABEL1-130. Explosion-proof flexible high-temperature heating cable with high power and self-regulating temperature GTG-KABEL1-130
In hot sections of the heating cable, the expansion of the heating element material almost completely disrupts the conductive paths. This causes the material's electrical resistance to become very high, significantly reducing thermal energy release.

The scope of application is explosion-hazardous areas of premises and outdoor installations, in accordance with the assigned explosion protection marking, the requirements of GOST IEC 60079-14-2013 and industry safety rules governing the use of this equipment in explosion-hazardous areas.

Advantages

  • Saving electricity.
  • Easy installation and operation.
  • No overheating effect.

Frequently bought together

Compliance with standards

GOST 31610.0-2014 (IEC 60079-0:2011)
GOST 31610.7-2012/ IEC 60079-7:2006
GOST IEC 60079-31-2013
GOST IEC 60079-30-1-2011
GOST 14254-2015
TR CU 012/2011
TR CU 004/2011

Certificates

Markings

Explosion protection marking
1Ex 60079-30-1 IIC T3 Gb X
Ex 60079-30-1 IIIC T140°C Db X
Degree of protection
IP66/IP67/IP68
Installation
Category II for gas subgroups IIA, IIB, IIC, zones 1, 2;
Category III for dust, explosive dust atmospheres containing volatile particles, non-conductive and conductive dust;
Non-hazardous zone of surface structures and open areas

Technical data

Ambient temperature, °C
-60...+135
Supply voltage, V
~230
Power, W
10, 15, 25, 38, 50, 63
Working position in space
Any
Climatic category
NF1 (as required NF2, NF3, NF4, NF5, HL1, HL2, HL3, HL5, T1, T2, T3, T5, MU1, MU2, MU3, MU4, W2.1 , W5 )

Design parameters

Technical characteristics of heating cables type GTG-KABEL1-130
Name GTG-KABEL1-130-10 GTG-KABEL1-130-15 GTG-KABEL1-130-25 GTG-KABEL1-130-38 GTG-KABEL1-130-50 GTG-KABEL1-130-63
Nominal power, W/m 10 ±10% 15 ±10% 25 ±10% 38 ±10% 50 ±10% 63 ±10%
Maximum supported temperature, °C +(135±10) +(135±10) +(135±10) +(135±10) +(135±10) +(135±10)
Maximum allowable temperature without load (1000 hours in total) +230 +230 +230 +230 +230 +230
Minimum installation temperature, °C -60 -60 -60 -60 -60 -60
Nominal cable size, mm 13.3x5.5 13.3x5.5 13.3x5.5 13.3x5.5 13.3x5.5 13.3x5.5
Maximum length of the heating section at an ambient temperature of -20°C, m 100 100 100 100 100 100
Temperature class T3 T3 T3 T3 T3 T3
Cable sheath material teflon - fluoropolymer teflon - fluoropolymer teflon - fluoropolymer teflon - fluoropolymer teflon - fluoropolymer teflon - fluoropolymer
Maximum circuit length when using type "C" circuit breakers according to EN 60898 at 230V
Dimensions of the electrical protective installation Switch-on temperature, °C Maximum length of heating cable per circuit (m) at 230V AC
GTG-KABEL1-130-10 GTG-KABEL1-130-15 GTG-KABEL1-130-25 GTG-KABEL1-130-38 GTG-KABEL1-130-50 GTG-KABEL1-130-63
16A (-20°C) 105 84 50 40 20 15
(+10°C) 105 84 50 40 20 15
25A (-20°C) 170 137 95 80 35 25
(+10°C) 170 137 95 80 35 25
32A (-20°C) 220 179 125 100 50 30
(+10°C) 220 179 125 100 50 30
40A (-20°C) 275 226 160 120 60 40
(+10°C) 275 226 160 120 60 40

Options

Options, accessories and versions
Marking
Cable element for termination of heating cable
/GTG-ZGK
Marine version
/MORE
Non-explosion-proof design
/PROM

Additional information

Graph of the dependence of linear power on temperature for cables of the GTG-KABEL1-130 type
Power, W/m
Graph of the dependence of linear power on temperature GTG-KABEL1
Pipe temperature, °C

A – GTG-KABEL1-130-63

B – GTG-KABEL1-130-50

C – GTG-KABEL1-130-38

D – GTG-KABEL 1-130-25

E – GTG-KABEL1-130-15

F – GTG-KABEL1-130-10

Self-regulating cable device

Self-regulating cable device:

1. Current-carrying conductors made of twisted copper wire tinned with tin.

2. Thermistor element.

3. Internal insulation to provide dielectric strength, moisture resistance, impact and abrasion resistance, and chemical resistance to the heat-generating matrix.

4. External insulation.

5. Tinned copper protective braid.

6. The outer protective shell made of fluoropolymer is used in conditions of high humidity, as well as when exposed to organic substances and solvents or other aggressive substances in normal areas or areas classified as explosive.

Examples of fixing a heating cable to a pipe

An example of fixing a heating cable to a pipe

An example of fixing a heating cable to a pipe

An example of fixing a heating cable to a pipe

An example of fixing a heating cable to a pipe

An example of fixing a heating cable to a pipe

An example of fixing a heating cable to a pipe

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or
Model Breakdown
GTG-KABEL 1X - 2X - 3X / 4X – TU 28.21.13-041-72453807-2017
1X - Maximum supported operating temperature °C: 130
2X - Power, W: 10, 15, 25, 38, 50, 63
3X - Length in meters
4X - Options, accessories and versions

Example: GTG-KABEL1-130-50-60-TU 28.21.13-041-72453807-2017

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more