• Distribution and Terminal Boxes
  • Control and Automation Cabinets
  • Lighting Equipment
  • Control and Indicating Stations
  • Visual, Audible and Signaling Devices
  • Electrical Heating and Fans
  • Video Surveillance
  • IT equipment
  • Spark protection barriers and functional safety relays
  • Cable Glands, Conduits
  • Sockets, Plugs, Extension cords
  • Switches, Selectors Switches, Sensors
  • Control and Measuring Instruments
  • Cable/Pipe Transits
  • Electrical Components and Materials
Logo

BIG-K-2K-2/11 Intrinsic Safety Barrier Discrete Input

Product Description

An intrinsic safety barrier converts discrete signals, such as potential contacts, from a control system in a safe area into a current signal in a hazardous area. It can be used to control field devices such as intrinsically safe valves, audible alarms, etc.

Advantages

  • The input and output signals are galvanically isolated from each other. Power is supplied from the signal circuit.
  • The electronic circuits of the barriers are coated with varnish, which additionally protects the elements from external factors.
  • Mounting on the BIG-BAZA or MTL4500 backplane.
  • Speed ​​and ease of installation.
  • Availability of LED indication.

Compliance with standards

GOST 31610.0-2014
GOST 31610.11-2014
GOST IEC 60079-14-2013
TR CU 012/2011
GOST IEC 61000-6-4-2016
GOST 30804.6.2-2013

Certificates

Markings

Explosion protection marking
[Ex ia Ga] IIC
[Ex ia Ga] IIB
[Ex ia Ga] IIA
[Ex ia Ma] I
[Ex ia Da] IIIС
Main parameters
Response time ≤ 20 ms
Power consumption ≤ 1.6 W
Dielectric
strength
alternating current (intrinsically safe and non-intrinsically safe sides) ≥ 2500 V
Insulation resistance
(input/output)
≥ 100 MOhm
Operating temperature -20°C… +60°C
Storage temperature -40°C… +80°C
Dimensions width 15.8 mm
height 121.6 mm
depth 104.8 mm
Transfer parameters
Maximum safe voltage 250 V
Intrinsic safety parameters terminals 1, 2
II C : II B, IIIC: II A, I :
U0, B 25,2 25,2 25,2
I0, mA 125 125 125
P0, mW 790 790 790
C0, μF 0,107 0,82 2,9
L0, mH 1,5 4,5 12
Nutrition
Power supply =20-30 Reverse polarity protection
Input parameters
Input signal Potential contact
Output parameters
Output current ≤ 45 mA
Output voltage > 12.2 VDC
Response parameters
Open circuit voltage 21.5 VDC
Output circuit diagram
Output Parameter Diagram

Design parameters

Connection diagram
Overall dimensions

Options

Options, accessories and versions
Marking
Marine version
/MORE

Additional information

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more