RFBG-342-24DC Functional Safety Relay

Product Description

The safety relay is designed to duplicate the safety signal and is widely used in mechanical engineering and other industries.

Advantages

  • Single-channel design.
  • With feedback loop.
  • The safety function remains operational even if components fail.
Main parameters
Voltage range, V 24
Voltage tolerances, V 0,85… 1,1
Heat output, W ≤ 2.2 at =24 V, ≤ 5.4 at ~24 V
Current consumption at =24V, mA ≤ 50
Test pulse duration, ms, no more than 4
Cable resistance, Ohm 15
Input devices security contact
Signal type 4no + 2nz
Contact type forced management
Contact material AgSnO2 + 0.2 μm Au
Load characteristics AC-15: 5 A / 230 V, DC-13: 5 A / 24 V
Fuse characteristics 10A gL/gG(no), 6A gL/gG(no)
Switching on, ms, no more than 30
Opening, ms, no more than 20
Recovery time, ms 100
Electromagnetic compatibility IEC/EN 80947, IEC 61326-3-1, IEC/EN 61000-6-2, IEC/EN 61000-6-4
Nominal insulation voltage
, V AC
250
Nominal pulse voltage, V 6000 (1.2/50 µs)
Dielectric strength, V 1500 (within 1 min)
Gaps and leaks According to IEC 80947-1
Vibration, Hz 10…55 (0.35 mm)
Overvoltage category III
Degree of pollution 2
Degree of dust and moisture protection IP20
Operating temperature, °C -20…. +60
Storage temperature, °C -40…. +80
Altitude above sea level, m ≤ 2000
Number of operations, cycles 10 x 106
Security parameters
Safety Integrity Level (SIL) 3
Average diagnostic coverage (DC avg), % 99
Mean time to failure (MTTFD), years 164
Hardware Fault Tolerance (HFT) 1
Safe failure rate (SFF), not less than, % 99
Average probability of dangerous failure on demand (PFDavg/PTI) 1,53×10-5
Probability of failure per hour (PFH), 1/h 1,77×10-10
Stop category 0
Connection diagram

Additional information

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more