RFBG-122-RK-24DC Functional Safety Relay

Product Description

The RFBG series safety relay's input terminals receive signals for emergency stops, protective gates, and safety light curtains—i.e., signals from devices with normally closed contacts used for emergency braking or to protect people entering hazardous areas—and are widely used in mechanical engineering and other industries.

Advantages

  • 1oo2 architecture.
  • Detection of short circuits on contacts.
  • Controlled manual reset.
  • The safety function remains operational even if components fail.
  • Correct operation of the safety relay is tested automatically during each on-off cycle.
Main parameters
Voltage range, V ~/=24
Voltage tolerances, V 0,85… 1,1
Heat output, W ≤ 3.8 at =24 V
Current consumption at =24 V, mA ≤ 50
Cable resistance, Ohm 15
Input devices emergency stop button, safety gate
Signal type 2 instant action + 2 delayed action
Contact type forced management
Contact material AgSnO2
Load characteristics AC-15: 3 A / 230 V, DC-13: 3 A / 24 V
Fuse characteristics 10 A gL/gG(no)
Delay range T set,s 0.1… 80 (default, 10)
Time setting accuracy, % ±15
Response time, ms ≤150
Opening, ms Auto stop: ≤ 30, power failure: ≤ 100
Recovery time, ms Auto stop: ≤30 + Tust, power failure: ≤ 100
Power interruption, ms 20
Electromagnetic compatibility IEC/EN 80947, IEC 61326-3-1, IEC/EN 61000-6-2, IEC/EN 61000-6-4
Nominal insulation voltage
, V AC
250
Nominal pulse voltage, V 6000 (1.2/50 µs)
Dielectric strength, V 1500 (within 1 min)
Gaps and leaks According to IEC 80947-1
Vibration, Hz 10…55 (0.35 mm)
Overvoltage category III
Degree of pollution 2
Degree of dust and moisture protection IP20
Operating temperature, °C -20…. +60
Storage temperature, °C -40…. +80
Altitude above sea level, m ≤ 2000
Number of operations, cycles 10 x 106
Security parameters
Safety Integrity Level (SIL) 3
Average diagnostic coverage (DC avg), % 99 1)
90 2)
Mean time to failure (MTTFD), years 164 1)
161 2)
Hardware Fault Tolerance (HFT) 1
Safe failure rate (SFF), not less than, % 99
Average probability of dangerous failure on demand (PFDavg/PTI) 1,53×10-5 1)
1,59×10-5 2)
Probability of failure per hour (PFH), 1/h 1,77×10-10 1)
1,85×10-10 2)
Stop category 0 1)
1 2)
1) - for contacts without delay, 13/14
2) - for contacts with delay, contacts 37/38, 47/48
Connection diagram

Additional information

Possible applications:


Input: "Emergency stop", 2-channel.
With short-circuit signaling on contacts.
Controlled manual reset.
Output: 2 NO (instantaneous) + 2 NC (auxiliary, delayed).

Submit request

Quantity
Additional description
0 / 300

Drag files here

CAD " GORELTEX ", questionnaires, necessary documents

Remaining: 20.00 MB
or

Where to buy GORELTEX products

Saint Petersburg

Head office and production site

Telephone
Address
193149, Leningrad region, Vsevolozhsk district, Novosaratovka village, Rabochaya street, house 9, building 1
Read more

Moscow

Sales office

Telephone
Address
123112, Moscow, Presnenskaya Embankment, 6, building 2, business complex "Imperia Tower", floor 12, office No. 15
Read more

Kazan

Sales office

Telephone
Address
420061, Russia, Republic of Tatarstan, Kazan, st. Nikolay Ershova, 1A, Korston Business Center, floor 11, office No. 1110
Read more

Tyumen

Sales office and production site

Telephone
Address
625031, Russia, Tyumen, Shcherbakova St., 160G
Read more